开放市场环境下多源AGC系统交直流互联系统锁相环参数化

Q4 Engineering
Saha Debdeep, Saikia Lalit Chandra
{"title":"开放市场环境下多源AGC系统交直流互联系统锁相环参数化","authors":"Saha Debdeep, Saikia Lalit Chandra","doi":"10.1504/ijpelec.2023.127545","DOIUrl":null,"url":null,"abstract":"This article emphasises on deregulated AGC of a realistic multi-machine gas - thermal plant with dish-Stirling solar-thermal (DSTS) as additional power generation sources in each control area by taking into accounts of AC/DC with phase locked loop (PLL) dynamics. Eigenvalue analysis confirms the steadiness of the reasonable power system with various interconnections such as AC, AC/DC link and AC/DC with PLL dynamics. A series form of proportional-integral-derivative (PID) namely proportional gain cascaded with integral and double-derivative (PI+DD+) controller is employed as secondary controller in each control areas for robust AGC to carry out market transactions under deregulated environment. Exploring the system with different type of interconnections infer that proper tuning of PLL function parameters may synchronise the grid better than without employing PLL. The performance of PI+DD+ controller along with optimum PLL gains commensurate with wide variations in governor, turbine, fuel and compressor discharge time constant of gas turbine plant.","PeriodicalId":38624,"journal":{"name":"International Journal of Power Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Phase locked loop parameterisation in AC/DC interconnected system for a multi-source AGC system under open market environment\",\"authors\":\"Saha Debdeep, Saikia Lalit Chandra\",\"doi\":\"10.1504/ijpelec.2023.127545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article emphasises on deregulated AGC of a realistic multi-machine gas - thermal plant with dish-Stirling solar-thermal (DSTS) as additional power generation sources in each control area by taking into accounts of AC/DC with phase locked loop (PLL) dynamics. Eigenvalue analysis confirms the steadiness of the reasonable power system with various interconnections such as AC, AC/DC link and AC/DC with PLL dynamics. A series form of proportional-integral-derivative (PID) namely proportional gain cascaded with integral and double-derivative (PI+DD+) controller is employed as secondary controller in each control areas for robust AGC to carry out market transactions under deregulated environment. Exploring the system with different type of interconnections infer that proper tuning of PLL function parameters may synchronise the grid better than without employing PLL. The performance of PI+DD+ controller along with optimum PLL gains commensurate with wide variations in governor, turbine, fuel and compressor discharge time constant of gas turbine plant.\",\"PeriodicalId\":38624,\"journal\":{\"name\":\"International Journal of Power Electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/ijpelec.2023.127545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/ijpelec.2023.127545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

摘要

本文通过考虑带锁相环(PLL)动态的交流/直流,重点研究了一个实际的多机燃气热电厂在每个控制区域以碟形斯特林太阳能热(DSTS)作为附加发电源的解除管制的AGC。特征值分析证实了合理的具有交流、交直流链路和带锁相环动态的交直流等多种互联方式的电力系统的稳定性。采用比例-积分-导数(PID)串联形式,即比例增益级联积分和双导数(PI+DD+)控制器作为各控制区域的二级控制器,使鲁棒AGC在放松管制的环境下进行市场交易。通过对不同连接方式的系统进行研究,发现适当调整锁相环函数参数比不采用锁相环更能实现电网的同步。PI+DD+控制器与最优锁相环的性能与燃气轮机装置调速器、涡轮、燃料和压缩机排放时间常数的较大变化相适应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Phase locked loop parameterisation in AC/DC interconnected system for a multi-source AGC system under open market environment
This article emphasises on deregulated AGC of a realistic multi-machine gas - thermal plant with dish-Stirling solar-thermal (DSTS) as additional power generation sources in each control area by taking into accounts of AC/DC with phase locked loop (PLL) dynamics. Eigenvalue analysis confirms the steadiness of the reasonable power system with various interconnections such as AC, AC/DC link and AC/DC with PLL dynamics. A series form of proportional-integral-derivative (PID) namely proportional gain cascaded with integral and double-derivative (PI+DD+) controller is employed as secondary controller in each control areas for robust AGC to carry out market transactions under deregulated environment. Exploring the system with different type of interconnections infer that proper tuning of PLL function parameters may synchronise the grid better than without employing PLL. The performance of PI+DD+ controller along with optimum PLL gains commensurate with wide variations in governor, turbine, fuel and compressor discharge time constant of gas turbine plant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Power Electronics
International Journal of Power Electronics Engineering-Electrical and Electronic Engineering
CiteScore
1.30
自引率
0.00%
发文量
84
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信