{"title":"聚乳酸基质皮下植入肝细胞溶解的局部生物相容性和生化特征","authors":"E. A. Ivanova, A. N. Dzyuman, M. V. Dvornichenko","doi":"10.20538/1682-0363-2022-4-63-71","DOIUrl":null,"url":null,"abstract":"The aim of the study was to investigate local biocompatibility and systemic effects of nonwoven polylactide (PLA) matrices on blood and liver parameters after their subcutaneous implantation in Wistar rats. Materials and methods. Bioabsorbable fibrous PLA matrices were produced by electrospinning and had dimensions (10 × 10 mm², thickness of no more than 0.5 mm; fiber diameter in the matrix ~1 μm) appropriate for subcutaneous implantation in white laboratory rats. Polymer implants were sterilized in ethylene oxide vapor. Thirty days after the implantation of PLA matrices, local biocompatibility according to GOST ISO 10993-6-2011, cellular parameters (total leukocyte count, hemogram, erythrocyte count, hemoglobin concentration), and biochemical blood parameters (lactate concentration, alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels) were studied, and a standard histologic evaluation of the liver was performed. Results. PLA matrix samples were mild local irritants on a scale of 1–1.9 points according to GOST ISO 10993-6-2011 criteria 30 days after the subcutaneous implantation. The median density of distribution of multinucleated giant cells (MNGCs) in the connective tissue around and in PLA matrices was 1,500 (1,350; 1,550) per 1 mm² of a slice. Pronounced leukocytic reaction due to lymphocytosis was noted (an increase by 1.7 times compared with a sham-operated (SO) control group, р < 0.02). The absence of a significant neutrophil count in the blood revealed sterile inflammation proceeding in the subcutaneous tissue around the PLA materials. Normalization of hepatic cytolysis markers (ALT and AST activity) in the blood without pronounced changes in the structure of the liver and the number of binuclear hepatocytes was noted. These markers were increased in SO controls (ALT up to 123% and AST up to 142%, p < 0.001 compared with values in the intact group). Conclusion. Nonwoven PLA matrices are biocompatible with subcutaneous tissue, undergo bioresorption by MNGCs, and have a distant protective effect on the functional state of the liver in laboratory animals. Hypotheses on the detected systemic effect during subcutaneous implantation of PLA matrices were discussed; however, specific mechanisms require further study.","PeriodicalId":43691,"journal":{"name":"Byulleten Sibirskoy Meditsiny","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2023-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Local biocompatibility and biochemical profile of hepatic cytolysis in subcutaneous implantation of polylactide matrices\",\"authors\":\"E. A. Ivanova, A. N. Dzyuman, M. V. Dvornichenko\",\"doi\":\"10.20538/1682-0363-2022-4-63-71\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of the study was to investigate local biocompatibility and systemic effects of nonwoven polylactide (PLA) matrices on blood and liver parameters after their subcutaneous implantation in Wistar rats. Materials and methods. Bioabsorbable fibrous PLA matrices were produced by electrospinning and had dimensions (10 × 10 mm², thickness of no more than 0.5 mm; fiber diameter in the matrix ~1 μm) appropriate for subcutaneous implantation in white laboratory rats. Polymer implants were sterilized in ethylene oxide vapor. Thirty days after the implantation of PLA matrices, local biocompatibility according to GOST ISO 10993-6-2011, cellular parameters (total leukocyte count, hemogram, erythrocyte count, hemoglobin concentration), and biochemical blood parameters (lactate concentration, alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels) were studied, and a standard histologic evaluation of the liver was performed. Results. PLA matrix samples were mild local irritants on a scale of 1–1.9 points according to GOST ISO 10993-6-2011 criteria 30 days after the subcutaneous implantation. The median density of distribution of multinucleated giant cells (MNGCs) in the connective tissue around and in PLA matrices was 1,500 (1,350; 1,550) per 1 mm² of a slice. Pronounced leukocytic reaction due to lymphocytosis was noted (an increase by 1.7 times compared with a sham-operated (SO) control group, р < 0.02). The absence of a significant neutrophil count in the blood revealed sterile inflammation proceeding in the subcutaneous tissue around the PLA materials. Normalization of hepatic cytolysis markers (ALT and AST activity) in the blood without pronounced changes in the structure of the liver and the number of binuclear hepatocytes was noted. These markers were increased in SO controls (ALT up to 123% and AST up to 142%, p < 0.001 compared with values in the intact group). Conclusion. Nonwoven PLA matrices are biocompatible with subcutaneous tissue, undergo bioresorption by MNGCs, and have a distant protective effect on the functional state of the liver in laboratory animals. Hypotheses on the detected systemic effect during subcutaneous implantation of PLA matrices were discussed; however, specific mechanisms require further study.\",\"PeriodicalId\":43691,\"journal\":{\"name\":\"Byulleten Sibirskoy Meditsiny\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Byulleten Sibirskoy Meditsiny\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20538/1682-0363-2022-4-63-71\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Byulleten Sibirskoy Meditsiny","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20538/1682-0363-2022-4-63-71","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
摘要
研究非织造聚乳酸(PLA)基质在Wistar大鼠皮下植入后的局部生物相容性和对血液和肝脏参数的全身影响。材料和方法。采用静电纺丝法制备了可生物吸收的聚乳酸纤维基质,其尺寸为(10 × 10 mm²,厚度不大于0.5 mm;基质内纤维直径约1 μm,适合于实验室大鼠皮下植入。聚合物植入物在环氧乙烷蒸气中灭菌。在PLA基质植入30天后,按照GOST ISO 10993-6-2011进行局部生物相容性、细胞参数(白细胞总数、血象、红细胞计数、血红蛋白浓度)和血液生化参数(乳酸浓度、谷丙转氨酶(ALT)和天冬氨酸转氨酶(AST)水平)的研究,并对肝脏进行标准组织学评价。结果。根据GOST ISO 10993-6-2011标准,PLA基质样品在皮下植入30天后为1-1.9分的轻度局部刺激物。多核巨细胞(MNGCs)在结缔组织周围和PLA基质中的分布密度中位数为1500 (1350;每1平方毫米的切片1550美元。由于淋巴细胞增多引起明显的白细胞反应(与假手术(SO)对照组相比增加了1.7倍);0.02)。血液中没有明显的中性粒细胞计数,表明PLA材料周围的皮下组织发生了无菌炎症。血液中肝细胞溶解标志物(ALT和AST活性)恢复正常,肝脏结构和双核肝细胞数量未发生明显变化。这些标记物在SO对照中增加(ALT高达123%,AST高达142%,p <0.001与完整组比较)。结论。非织造PLA基质与皮下组织具有生物相容性,可被MNGCs生物吸收,对实验动物肝脏功能状态具有一定的保护作用。讨论了聚乳酸基质皮下植入过程中检测到的全身效应的假设;然而,具体机制需要进一步研究。
Local biocompatibility and biochemical profile of hepatic cytolysis in subcutaneous implantation of polylactide matrices
The aim of the study was to investigate local biocompatibility and systemic effects of nonwoven polylactide (PLA) matrices on blood and liver parameters after their subcutaneous implantation in Wistar rats. Materials and methods. Bioabsorbable fibrous PLA matrices were produced by electrospinning and had dimensions (10 × 10 mm², thickness of no more than 0.5 mm; fiber diameter in the matrix ~1 μm) appropriate for subcutaneous implantation in white laboratory rats. Polymer implants were sterilized in ethylene oxide vapor. Thirty days after the implantation of PLA matrices, local biocompatibility according to GOST ISO 10993-6-2011, cellular parameters (total leukocyte count, hemogram, erythrocyte count, hemoglobin concentration), and biochemical blood parameters (lactate concentration, alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels) were studied, and a standard histologic evaluation of the liver was performed. Results. PLA matrix samples were mild local irritants on a scale of 1–1.9 points according to GOST ISO 10993-6-2011 criteria 30 days after the subcutaneous implantation. The median density of distribution of multinucleated giant cells (MNGCs) in the connective tissue around and in PLA matrices was 1,500 (1,350; 1,550) per 1 mm² of a slice. Pronounced leukocytic reaction due to lymphocytosis was noted (an increase by 1.7 times compared with a sham-operated (SO) control group, р < 0.02). The absence of a significant neutrophil count in the blood revealed sterile inflammation proceeding in the subcutaneous tissue around the PLA materials. Normalization of hepatic cytolysis markers (ALT and AST activity) in the blood without pronounced changes in the structure of the liver and the number of binuclear hepatocytes was noted. These markers were increased in SO controls (ALT up to 123% and AST up to 142%, p < 0.001 compared with values in the intact group). Conclusion. Nonwoven PLA matrices are biocompatible with subcutaneous tissue, undergo bioresorption by MNGCs, and have a distant protective effect on the functional state of the liver in laboratory animals. Hypotheses on the detected systemic effect during subcutaneous implantation of PLA matrices were discussed; however, specific mechanisms require further study.