2018年4月至2019年3月,PT. P prabumuli对SKG X压缩机的操作限制分析

None Azka Roby Antari, None Zulfan Yusuf Asdan
{"title":"2018年4月至2019年3月,PT. P prabumuli对SKG X压缩机的操作限制分析","authors":"None Azka Roby Antari, None Zulfan Yusuf Asdan","doi":"10.53625/jcijurnalcakrawalailmiah.v3i2.6725","DOIUrl":null,"url":null,"abstract":"The gas compressor engine is the main equipment at the Gas Compressor Station (SKG). The working principle is gas compression, the compressor has rotating impeller blades pushing the gas into the diffuser forcing the gas to move into the vessel until the pressure on the gas increases. At SKG X PT. P Prabumulih who supplies gas to PT. Pusri, there are 4 compressor units (A, B, C, D), where in one day three compressor units are operating, and one compressor unit is in stand-by condition or under maintenance so it does not operate. The total operating hours of all compressors in one day is 72 hours and total stand-by hours are 24 hours. This quantitative research analyzes compressor performance data to obtain operational constraints experienced by compressors and their impact on compressor performance.
 Based on the results of the analysis, the hours of operation and stand-by of the 4 compressor units during a year did not run normally, due to some troubles with the compressor, a total of 25,773 working hours, 9,075 hours of standby, 444 hours of damage/loss. No compressor works 100% full, compressor B has the worst breakdown hours with 173 hours (3.64% of the total breakdown hours). During the year, there were 59 occurrences of damage to the compressor consisting of 26 types of damage with the peak performance decline occurring between June and July, which resulted in a loss of 2% of productive hours per year. This certainly has an impact on the loss of production target volume.","PeriodicalId":470943,"journal":{"name":"Jurnal Cakrawala Ilmiah","volume":"13 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ANALISIS KENDALA OPERASIONAL PADA KOMPRESOR SKG X MILIK PT. P PRABUMULIH PADA PERIODE APRIL 2018 – MARET 2019\",\"authors\":\"None Azka Roby Antari, None Zulfan Yusuf Asdan\",\"doi\":\"10.53625/jcijurnalcakrawalailmiah.v3i2.6725\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The gas compressor engine is the main equipment at the Gas Compressor Station (SKG). The working principle is gas compression, the compressor has rotating impeller blades pushing the gas into the diffuser forcing the gas to move into the vessel until the pressure on the gas increases. At SKG X PT. P Prabumulih who supplies gas to PT. Pusri, there are 4 compressor units (A, B, C, D), where in one day three compressor units are operating, and one compressor unit is in stand-by condition or under maintenance so it does not operate. The total operating hours of all compressors in one day is 72 hours and total stand-by hours are 24 hours. This quantitative research analyzes compressor performance data to obtain operational constraints experienced by compressors and their impact on compressor performance.
 Based on the results of the analysis, the hours of operation and stand-by of the 4 compressor units during a year did not run normally, due to some troubles with the compressor, a total of 25,773 working hours, 9,075 hours of standby, 444 hours of damage/loss. No compressor works 100% full, compressor B has the worst breakdown hours with 173 hours (3.64% of the total breakdown hours). During the year, there were 59 occurrences of damage to the compressor consisting of 26 types of damage with the peak performance decline occurring between June and July, which resulted in a loss of 2% of productive hours per year. This certainly has an impact on the loss of production target volume.\",\"PeriodicalId\":470943,\"journal\":{\"name\":\"Jurnal Cakrawala Ilmiah\",\"volume\":\"13 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Cakrawala Ilmiah\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53625/jcijurnalcakrawalailmiah.v3i2.6725\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Cakrawala Ilmiah","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53625/jcijurnalcakrawalailmiah.v3i2.6725","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

燃气压缩机发动机是燃气压气站(SKG)的主要设备。工作原理是气体压缩,压缩机有旋转的叶轮叶片推动气体进入扩散器,迫使气体进入容器,直到气体上的压力增加。SKG X PT. P Prabumulih为PT. Pusri提供天然气,有4台压缩机组(A、B、C、D),其中3台压缩机组在一天内运行,1台压缩机组处于备用状态或维修中,因此无法运行。所有压缩机一天的总运行时间为72小时,总待机时间为24小时。本研究通过对压缩机性能数据的定量分析,得出了压缩机所经历的运行约束及其对压缩机性能的影响。 根据分析结果,4台压缩机机组在一年内运行和待机时数未正常运行,由于压缩机出现一些故障,共工作时数25,773小时,待机时数9,075小时,损坏/损失444小时。没有一台压缩机100%满负荷工作,压缩机B的故障时间最长,为173小时(占总故障时间的3.64%)。在这一年中,压缩机发生了59次损坏,包括26种类型的损坏,性能下降的高峰期发生在6月至7月,导致每年损失2%的生产小时。这当然会对生产目标数量的损失产生影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ANALISIS KENDALA OPERASIONAL PADA KOMPRESOR SKG X MILIK PT. P PRABUMULIH PADA PERIODE APRIL 2018 – MARET 2019
The gas compressor engine is the main equipment at the Gas Compressor Station (SKG). The working principle is gas compression, the compressor has rotating impeller blades pushing the gas into the diffuser forcing the gas to move into the vessel until the pressure on the gas increases. At SKG X PT. P Prabumulih who supplies gas to PT. Pusri, there are 4 compressor units (A, B, C, D), where in one day three compressor units are operating, and one compressor unit is in stand-by condition or under maintenance so it does not operate. The total operating hours of all compressors in one day is 72 hours and total stand-by hours are 24 hours. This quantitative research analyzes compressor performance data to obtain operational constraints experienced by compressors and their impact on compressor performance. Based on the results of the analysis, the hours of operation and stand-by of the 4 compressor units during a year did not run normally, due to some troubles with the compressor, a total of 25,773 working hours, 9,075 hours of standby, 444 hours of damage/loss. No compressor works 100% full, compressor B has the worst breakdown hours with 173 hours (3.64% of the total breakdown hours). During the year, there were 59 occurrences of damage to the compressor consisting of 26 types of damage with the peak performance decline occurring between June and July, which resulted in a loss of 2% of productive hours per year. This certainly has an impact on the loss of production target volume.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信