不同关节疾病患者血清及滑液组织蛋白酶B、H的测定。

D Gabrijelcic, A Annan-Prah, B Rodic, B Rozman, V Cotic, V Turk
{"title":"不同关节疾病患者血清及滑液组织蛋白酶B、H的测定。","authors":"D Gabrijelcic,&nbsp;A Annan-Prah,&nbsp;B Rodic,&nbsp;B Rozman,&nbsp;V Cotic,&nbsp;V Turk","doi":"10.1515/cclm.1990.28.3.149","DOIUrl":null,"url":null,"abstract":"<p><p>Synovial fluids and sera of patients with inflammatory and metabolic joint diseases contain different cysteine proteinases. The quantities of cathepsins B and H were determined by newly developed specific enzyme-linked immunoassay tests (ELISA), with detection limits of 0.5 microgram/l for cathepsin B and 3 micrograms/l for cathepsin H. The values of cathepsin B in normal sera ranged from 0.6 microgram/l to 2 micrograms/l, whereas in sera of patients with joint diseases they ranged from 1.7 micrograms/l to 18 micrograms/l. Cathepsin H was not found in sera (values below 3 micrograms/l), but was measurable in patients' synovial fluids. Patients with rheumatoid arthritis have on average the highest values of cathepsin B in synovial fluids, whereas patients with undifferentiated arthritis have the highest values of cathepsin H. The results show that cathepsins B and H are present in arthritic synovial fluids, where they may be implicated in destructive processes. There is yet no clear correlation between the quantity of each cathepsin released in synovia and the clinical diagnosis or the stage of the disease.</p>","PeriodicalId":15649,"journal":{"name":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","volume":"28 3","pages":"149-53"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1990.28.3.149","citationCount":"46","resultStr":"{\"title\":\"Determination of cathepsins B and H in sera and synovial fluids of patients with different joint diseases.\",\"authors\":\"D Gabrijelcic,&nbsp;A Annan-Prah,&nbsp;B Rodic,&nbsp;B Rozman,&nbsp;V Cotic,&nbsp;V Turk\",\"doi\":\"10.1515/cclm.1990.28.3.149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Synovial fluids and sera of patients with inflammatory and metabolic joint diseases contain different cysteine proteinases. The quantities of cathepsins B and H were determined by newly developed specific enzyme-linked immunoassay tests (ELISA), with detection limits of 0.5 microgram/l for cathepsin B and 3 micrograms/l for cathepsin H. The values of cathepsin B in normal sera ranged from 0.6 microgram/l to 2 micrograms/l, whereas in sera of patients with joint diseases they ranged from 1.7 micrograms/l to 18 micrograms/l. Cathepsin H was not found in sera (values below 3 micrograms/l), but was measurable in patients' synovial fluids. Patients with rheumatoid arthritis have on average the highest values of cathepsin B in synovial fluids, whereas patients with undifferentiated arthritis have the highest values of cathepsin H. The results show that cathepsins B and H are present in arthritic synovial fluids, where they may be implicated in destructive processes. There is yet no clear correlation between the quantity of each cathepsin released in synovia and the clinical diagnosis or the stage of the disease.</p>\",\"PeriodicalId\":15649,\"journal\":{\"name\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"volume\":\"28 3\",\"pages\":\"149-53\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1515/cclm.1990.28.3.149\",\"citationCount\":\"46\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm.1990.28.3.149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1990.28.3.149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 46

摘要

炎性和代谢性关节疾病患者的滑液和血清中含有不同的半胱氨酸蛋白酶。组织蛋白酶B和H的检测限分别为0.5微克/升和3微克/升,正常血清中组织蛋白酶B的检测限为0.6微克/升至2微克/升,而关节疾病患者血清中组织蛋白酶B的检测限为1.7微克/升至18微克/升。血清中未发现组织蛋白酶H(值低于3微克/升),但在患者滑液中可测量到。类风湿性关节炎患者在滑液中组织蛋白酶B的平均值最高,而未分化关节炎患者的组织蛋白酶H的平均值最高。结果表明,组织蛋白酶B和H存在于关节炎滑液中,它们可能与破坏性过程有关。滑膜中各组织蛋白酶的释放量与临床诊断或疾病分期之间尚无明确的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of cathepsins B and H in sera and synovial fluids of patients with different joint diseases.

Synovial fluids and sera of patients with inflammatory and metabolic joint diseases contain different cysteine proteinases. The quantities of cathepsins B and H were determined by newly developed specific enzyme-linked immunoassay tests (ELISA), with detection limits of 0.5 microgram/l for cathepsin B and 3 micrograms/l for cathepsin H. The values of cathepsin B in normal sera ranged from 0.6 microgram/l to 2 micrograms/l, whereas in sera of patients with joint diseases they ranged from 1.7 micrograms/l to 18 micrograms/l. Cathepsin H was not found in sera (values below 3 micrograms/l), but was measurable in patients' synovial fluids. Patients with rheumatoid arthritis have on average the highest values of cathepsin B in synovial fluids, whereas patients with undifferentiated arthritis have the highest values of cathepsin H. The results show that cathepsins B and H are present in arthritic synovial fluids, where they may be implicated in destructive processes. There is yet no clear correlation between the quantity of each cathepsin released in synovia and the clinical diagnosis or the stage of the disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信