{"title":"狭窄动脉导管血流轴向速度计算的分析研究","authors":"Hawraa Dheyaa Asfoor, Esam A. Alnussairy","doi":"10.31185/wjps.64","DOIUrl":null,"url":null,"abstract":"The current study reviews the effect of blood flow characteristics through stenosis during angioplasty, considering that blood is a steady, Newtonian fluid with a steady and incompressible, these vessels are purified by the use of catheters. The engineering of the arterial part is a tube with overlapping stenosis in the lumen of the arteries of the patient, causing a defect in the cardiovascular system, was built Mathematically for the movement of physiological fluid representing blood in the gap between two eccentric tubes (eccentric - ring flows), where the inlet tube is a uniform solid representing the moving catheter while the other is a tapered cylindrical tube representing the artery with intervening stenosis. The problem was analyzed to find the axial velocity approximate solution.","PeriodicalId":167115,"journal":{"name":"Wasit Journal of Pure sciences","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical study for calculating the axial velocity for blood flow through the catheter of a stenosed artery\",\"authors\":\"Hawraa Dheyaa Asfoor, Esam A. Alnussairy\",\"doi\":\"10.31185/wjps.64\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current study reviews the effect of blood flow characteristics through stenosis during angioplasty, considering that blood is a steady, Newtonian fluid with a steady and incompressible, these vessels are purified by the use of catheters. The engineering of the arterial part is a tube with overlapping stenosis in the lumen of the arteries of the patient, causing a defect in the cardiovascular system, was built Mathematically for the movement of physiological fluid representing blood in the gap between two eccentric tubes (eccentric - ring flows), where the inlet tube is a uniform solid representing the moving catheter while the other is a tapered cylindrical tube representing the artery with intervening stenosis. The problem was analyzed to find the axial velocity approximate solution.\",\"PeriodicalId\":167115,\"journal\":{\"name\":\"Wasit Journal of Pure sciences\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wasit Journal of Pure sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31185/wjps.64\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wasit Journal of Pure sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31185/wjps.64","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前的研究回顾了血管成形术中狭窄血流特性的影响,考虑到血液是一种稳定的牛顿流体,具有稳定和不可压缩的特性,这些血管通过导管的使用得到净化。动脉部分的工程是在患者的动脉腔中有一个重叠狭窄的管,导致心血管系统的缺陷,为代表血液的生理液体在两个偏心管(偏心环流)之间的间隙中运动而建立数学模型,其中入口管是一个均匀的实体,代表运动导管,另一个是一个锥形的圆柱形管,代表中间狭窄的动脉。对问题进行了分析,找到了轴向速度的近似解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical study for calculating the axial velocity for blood flow through the catheter of a stenosed artery
The current study reviews the effect of blood flow characteristics through stenosis during angioplasty, considering that blood is a steady, Newtonian fluid with a steady and incompressible, these vessels are purified by the use of catheters. The engineering of the arterial part is a tube with overlapping stenosis in the lumen of the arteries of the patient, causing a defect in the cardiovascular system, was built Mathematically for the movement of physiological fluid representing blood in the gap between two eccentric tubes (eccentric - ring flows), where the inlet tube is a uniform solid representing the moving catheter while the other is a tapered cylindrical tube representing the artery with intervening stenosis. The problem was analyzed to find the axial velocity approximate solution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信