用于生物医学信号数字化的低功率前置放大器

N. ALjehani, M. Abbas
{"title":"用于生物医学信号数字化的低功率前置放大器","authors":"N. ALjehani, M. Abbas","doi":"10.23919/MIXDES49814.2020.9155753","DOIUrl":null,"url":null,"abstract":"This paper presents a low power, low noise preamplifier stage with simple common mode desensitization circuit for dynamic comparators. The target application of the proposed circuit is analog to digital converter for biomedical applications. Adopting TSMC $0.18\\mu \\mathrm{m}$ technology, the proposed circuit is designed to work in weak inversion using $\\mathrm{g}_{\\mathrm{m}}/\\mathrm{I}_{\\mathrm{D}}$ design methodology. The simulation results show that the preamplifier stage consumes less than 32nW using power supply of 0.75V. The input referred noise is $17\\mu\\mathrm{V}$, DC gain of 43.15dB and unity gain frequency of 300 kHz.","PeriodicalId":145224,"journal":{"name":"2020 27th International Conference on Mixed Design of Integrated Circuits and System (MIXDES)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Low Power Preamplifier for Biomedical Signal Digitization\",\"authors\":\"N. ALjehani, M. Abbas\",\"doi\":\"10.23919/MIXDES49814.2020.9155753\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a low power, low noise preamplifier stage with simple common mode desensitization circuit for dynamic comparators. The target application of the proposed circuit is analog to digital converter for biomedical applications. Adopting TSMC $0.18\\\\mu \\\\mathrm{m}$ technology, the proposed circuit is designed to work in weak inversion using $\\\\mathrm{g}_{\\\\mathrm{m}}/\\\\mathrm{I}_{\\\\mathrm{D}}$ design methodology. The simulation results show that the preamplifier stage consumes less than 32nW using power supply of 0.75V. The input referred noise is $17\\\\mu\\\\mathrm{V}$, DC gain of 43.15dB and unity gain frequency of 300 kHz.\",\"PeriodicalId\":145224,\"journal\":{\"name\":\"2020 27th International Conference on Mixed Design of Integrated Circuits and System (MIXDES)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 27th International Conference on Mixed Design of Integrated Circuits and System (MIXDES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/MIXDES49814.2020.9155753\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 27th International Conference on Mixed Design of Integrated Circuits and System (MIXDES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/MIXDES49814.2020.9155753","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种低功耗、低噪声的前置放大级,具有简单的共模脱敏电路,用于动态比较器。该电路的目标应用是用于生物医学应用的模拟数字转换器。采用台积电$0.18\mu \mathrm{m}$技术,采用$\mathrm{g}_ \mathrm{m}}/\mathrm{I}_{\mathrm{D}}$设计方法设计弱反转电路。仿真结果表明,在0.75V电源下,前置放大级功耗小于32nW。输入参考噪声为$17\mu\ mathm {V}$,直流增益为43.15dB,单位增益频率为300 kHz。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Low Power Preamplifier for Biomedical Signal Digitization
This paper presents a low power, low noise preamplifier stage with simple common mode desensitization circuit for dynamic comparators. The target application of the proposed circuit is analog to digital converter for biomedical applications. Adopting TSMC $0.18\mu \mathrm{m}$ technology, the proposed circuit is designed to work in weak inversion using $\mathrm{g}_{\mathrm{m}}/\mathrm{I}_{\mathrm{D}}$ design methodology. The simulation results show that the preamplifier stage consumes less than 32nW using power supply of 0.75V. The input referred noise is $17\mu\mathrm{V}$, DC gain of 43.15dB and unity gain frequency of 300 kHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信