N. Leboeuf, T. Boileau, B. Nahid-Mobarakeh, F. Meibody-Tabar
{"title":"基于反电动势估计和残差分析的电流控制永磁驱动器故障检测","authors":"N. Leboeuf, T. Boileau, B. Nahid-Mobarakeh, F. Meibody-Tabar","doi":"10.1109/IAS.2010.5616894","DOIUrl":null,"url":null,"abstract":"In this paper, a new technique for on-line detecting inter-turn stator winding fault in Permanent Magnet Synchronous Machine (PMSM) is presented. It is based on a residual analysis improved by adding a back-EMF waveform estimation system which allows identifying real back-EMF frequency components of the healthy machine. Then, a simple current residual monitoring permits us to detect the fault and its severity. Simulations and experimentations validate the proposed method and its efficiency.","PeriodicalId":317643,"journal":{"name":"2010 IEEE Industry Applications Society Annual Meeting","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Fault Detection in a Current Controlled PM Drive Using Back-EMF Estimation and Residual Analysis\",\"authors\":\"N. Leboeuf, T. Boileau, B. Nahid-Mobarakeh, F. Meibody-Tabar\",\"doi\":\"10.1109/IAS.2010.5616894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new technique for on-line detecting inter-turn stator winding fault in Permanent Magnet Synchronous Machine (PMSM) is presented. It is based on a residual analysis improved by adding a back-EMF waveform estimation system which allows identifying real back-EMF frequency components of the healthy machine. Then, a simple current residual monitoring permits us to detect the fault and its severity. Simulations and experimentations validate the proposed method and its efficiency.\",\"PeriodicalId\":317643,\"journal\":{\"name\":\"2010 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2010.5616894\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2010.5616894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault Detection in a Current Controlled PM Drive Using Back-EMF Estimation and Residual Analysis
In this paper, a new technique for on-line detecting inter-turn stator winding fault in Permanent Magnet Synchronous Machine (PMSM) is presented. It is based on a residual analysis improved by adding a back-EMF waveform estimation system which allows identifying real back-EMF frequency components of the healthy machine. Then, a simple current residual monitoring permits us to detect the fault and its severity. Simulations and experimentations validate the proposed method and its efficiency.