{"title":"一种用于膝关节运动分析的改进CT -透视配准算法","authors":"M. Pickering, J. Scarvell, Paul N. Smith","doi":"10.1109/ICDSP.2009.5201122","DOIUrl":null,"url":null,"abstract":"Understanding the kinematics of the knee joint as it undergoes normal physical activities is an important goal of the orthopaedic research community. The limitations of previous approaches to capturing knee kinematics include the requirement for tantalum beads to be implanted prior to imaging and the use of biplanar X-ray imaging which is not commonly available in hospital imaging departments. A recently proposed alternative approach is to register 3D CT data with individual 2D video frames of the knee captured using single-plane X-ray fluoroscopy. The main limitation of this approach has been the inaccuracy of the registration algorithm for out-of-plane translation. In this paper we propose an improved registration algorithm which uses the relatively new Cross-Cumulative Residual Entropy similarity measure. Experimental results show that the accuracy of our proposed technique is superior to previous approaches particularly for out-of-plane translation.","PeriodicalId":409669,"journal":{"name":"2009 16th International Conference on Digital Signal Processing","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"An improved CT to fluoroscopy registration algorithm for the kinematic analysis of knee joints\",\"authors\":\"M. Pickering, J. Scarvell, Paul N. Smith\",\"doi\":\"10.1109/ICDSP.2009.5201122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Understanding the kinematics of the knee joint as it undergoes normal physical activities is an important goal of the orthopaedic research community. The limitations of previous approaches to capturing knee kinematics include the requirement for tantalum beads to be implanted prior to imaging and the use of biplanar X-ray imaging which is not commonly available in hospital imaging departments. A recently proposed alternative approach is to register 3D CT data with individual 2D video frames of the knee captured using single-plane X-ray fluoroscopy. The main limitation of this approach has been the inaccuracy of the registration algorithm for out-of-plane translation. In this paper we propose an improved registration algorithm which uses the relatively new Cross-Cumulative Residual Entropy similarity measure. Experimental results show that the accuracy of our proposed technique is superior to previous approaches particularly for out-of-plane translation.\",\"PeriodicalId\":409669,\"journal\":{\"name\":\"2009 16th International Conference on Digital Signal Processing\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 16th International Conference on Digital Signal Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDSP.2009.5201122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 16th International Conference on Digital Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDSP.2009.5201122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

了解膝关节在进行正常身体活动时的运动学是骨科研究界的一个重要目标。以前捕获膝关节运动学的方法的局限性包括要求在成像之前植入钽珠和使用双平面x射线成像,这在医院成像部门不常见。最近提出的一种替代方法是将3D CT数据与使用单平面x射线透视捕获的单个膝关节2D视频帧进行注册。这种方法的主要限制是面外平移的配准算法不准确。本文提出了一种改进的配准算法,该算法使用了相对较新的交叉累积残差熵相似性度量。实验结果表明,该方法的精度优于以往的方法,特别是在平面外平移方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An improved CT to fluoroscopy registration algorithm for the kinematic analysis of knee joints
Understanding the kinematics of the knee joint as it undergoes normal physical activities is an important goal of the orthopaedic research community. The limitations of previous approaches to capturing knee kinematics include the requirement for tantalum beads to be implanted prior to imaging and the use of biplanar X-ray imaging which is not commonly available in hospital imaging departments. A recently proposed alternative approach is to register 3D CT data with individual 2D video frames of the knee captured using single-plane X-ray fluoroscopy. The main limitation of this approach has been the inaccuracy of the registration algorithm for out-of-plane translation. In this paper we propose an improved registration algorithm which uses the relatively new Cross-Cumulative Residual Entropy similarity measure. Experimental results show that the accuracy of our proposed technique is superior to previous approaches particularly for out-of-plane translation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信