在哈萨克斯坦西部,由架空电缆制成的架空电线上的猛禽死亡

M. Pestov, Nurlan V. Ongarbayev, I. Smelansky, D. Denisov
{"title":"在哈萨克斯坦西部,由架空电缆制成的架空电线上的猛禽死亡","authors":"M. Pestov, Nurlan V. Ongarbayev, I. Smelansky, D. Denisov","doi":"10.19074/1814-8654-2020-40-52-62","DOIUrl":null,"url":null,"abstract":"Medium-capacity (6–20kV) overhead power lines made of aerial bundled cables (ABC) were inspected to identify deaths of birds of prey in western Kazakhstan in summer 2017 (Aktobe Province) and autumn2019 (Mangystau Province). The results show that the use of ABC in itself does not completely prevent deaths of birds. Birds die from electrocution caused by contact with lightning overvoltage protectors. The level of hazard to the birds depends on the design of such protectors. The conclusion was made that the safety of birds should be ensured when designing overhead power lines, including ABC lines. It is recommended to use primarily the lightning overvoltage protectors that ensure safety of birds.","PeriodicalId":330422,"journal":{"name":"Raptors Conservation","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Deaths of Birds of Prey on Overhead Power Lines Made of Aerial Bundled Cables in Western Kazakhstan\",\"authors\":\"M. Pestov, Nurlan V. Ongarbayev, I. Smelansky, D. Denisov\",\"doi\":\"10.19074/1814-8654-2020-40-52-62\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medium-capacity (6–20kV) overhead power lines made of aerial bundled cables (ABC) were inspected to identify deaths of birds of prey in western Kazakhstan in summer 2017 (Aktobe Province) and autumn2019 (Mangystau Province). The results show that the use of ABC in itself does not completely prevent deaths of birds. Birds die from electrocution caused by contact with lightning overvoltage protectors. The level of hazard to the birds depends on the design of such protectors. The conclusion was made that the safety of birds should be ensured when designing overhead power lines, including ABC lines. It is recommended to use primarily the lightning overvoltage protectors that ensure safety of birds.\",\"PeriodicalId\":330422,\"journal\":{\"name\":\"Raptors Conservation\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Raptors Conservation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19074/1814-8654-2020-40-52-62\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Raptors Conservation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19074/1814-8654-2020-40-52-62","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在2017年夏季(阿克托别省)和2019年秋季(曼吉斯州省)对由架空电缆(ABC)制成的中等容量(6-20kV)架空电力线进行了检查,以确定哈萨克斯坦西部的猛禽死亡情况。结果表明,使用ABC本身并不能完全防止鸟类死亡。鸟类因接触雷击过电压保护器而触电死亡。对鸟类的危害程度取决于这些保护器的设计。得出结论:在设计包括ABC线路在内的架空电力线路时,应确保鸟类的安全。建议主要使用雷电过电压保护器,以确保鸟类的安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Deaths of Birds of Prey on Overhead Power Lines Made of Aerial Bundled Cables in Western Kazakhstan
Medium-capacity (6–20kV) overhead power lines made of aerial bundled cables (ABC) were inspected to identify deaths of birds of prey in western Kazakhstan in summer 2017 (Aktobe Province) and autumn2019 (Mangystau Province). The results show that the use of ABC in itself does not completely prevent deaths of birds. Birds die from electrocution caused by contact with lightning overvoltage protectors. The level of hazard to the birds depends on the design of such protectors. The conclusion was made that the safety of birds should be ensured when designing overhead power lines, including ABC lines. It is recommended to use primarily the lightning overvoltage protectors that ensure safety of birds.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信