{"title":"具有四边形特性的通信辅助距离继电器对相间故障电阻的鲁棒性","authors":"H. Shateri, S. Jamali","doi":"10.1109/POWERCON.2010.5666018","DOIUrl":null,"url":null,"abstract":"This paper discusses the maximum fault resistance, which can be tolerated by a communication aided distance relay with Quadrilateral characteristic in the case of inter phase, phase to phase and three phase, faults. This is defined as the boundary fault resistance, which is the maximum fault resistance that the relay can discriminate between in-zone and out-of-zone faults correctly. The robustness criterion is defined based on the boundary fault resistance. In order to achieve this, the related equations are derived and then the boundary fault resistance curve and robustness criterion are presented.","PeriodicalId":169553,"journal":{"name":"2010 International Conference on Power System Technology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Robustness of communication aided distance relay with Quadrilateral characteristic against inter phase fault resistance\",\"authors\":\"H. Shateri, S. Jamali\",\"doi\":\"10.1109/POWERCON.2010.5666018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the maximum fault resistance, which can be tolerated by a communication aided distance relay with Quadrilateral characteristic in the case of inter phase, phase to phase and three phase, faults. This is defined as the boundary fault resistance, which is the maximum fault resistance that the relay can discriminate between in-zone and out-of-zone faults correctly. The robustness criterion is defined based on the boundary fault resistance. In order to achieve this, the related equations are derived and then the boundary fault resistance curve and robustness criterion are presented.\",\"PeriodicalId\":169553,\"journal\":{\"name\":\"2010 International Conference on Power System Technology\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Power System Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2010.5666018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2010.5666018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Robustness of communication aided distance relay with Quadrilateral characteristic against inter phase fault resistance
This paper discusses the maximum fault resistance, which can be tolerated by a communication aided distance relay with Quadrilateral characteristic in the case of inter phase, phase to phase and three phase, faults. This is defined as the boundary fault resistance, which is the maximum fault resistance that the relay can discriminate between in-zone and out-of-zone faults correctly. The robustness criterion is defined based on the boundary fault resistance. In order to achieve this, the related equations are derived and then the boundary fault resistance curve and robustness criterion are presented.