D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray
{"title":"用于大VA、PWM驱动系统的12/24脉冲自动连接整流器的设计考虑","authors":"D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray","doi":"10.1109/APEC.1999.750475","DOIUrl":null,"url":null,"abstract":"Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.","PeriodicalId":287192,"journal":{"name":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Design considerations for 12/24-pulse auto-connected rectifiers for large VA, PWM drive systems\",\"authors\":\"D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray\",\"doi\":\"10.1109/APEC.1999.750475\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.\",\"PeriodicalId\":287192,\"journal\":{\"name\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1999.750475\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1999.750475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design considerations for 12/24-pulse auto-connected rectifiers for large VA, PWM drive systems
Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.