用于大VA、PWM驱动系统的12/24脉冲自动连接整流器的设计考虑

D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray
{"title":"用于大VA、PWM驱动系统的12/24脉冲自动连接整流器的设计考虑","authors":"D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray","doi":"10.1109/APEC.1999.750475","DOIUrl":null,"url":null,"abstract":"Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.","PeriodicalId":287192,"journal":{"name":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Design considerations for 12/24-pulse auto-connected rectifiers for large VA, PWM drive systems\",\"authors\":\"D. Rendusara, K.J. Slater, B.S. Lee, P. Enjeti, I. Pitel, W. Gray\",\"doi\":\"10.1109/APEC.1999.750475\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.\",\"PeriodicalId\":287192,\"journal\":{\"name\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1999.750475\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1999.750475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

自动连接多脉冲(12/24脉冲)整流方案是降低PWM电机驱动系统中线路电流谐波的经济有效方法。采用这些方案来提高公用事业电能质量需要仔细注意几个设计考虑因素。特别是:直流电压在空载时的偏移;原有电压畸变的影响;阻抗不匹配;整流电流分担时二极管降差不等;并对性能进行了全面分析。讨论了提高12/24脉冲整流系统性能的几种纠正措施。最后,详细讨论了采用12/24脉冲整流系统改造的460 V, 60 Hz, 400 kVA商用ASD的实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design considerations for 12/24-pulse auto-connected rectifiers for large VA, PWM drive systems
Auto-connected multipulse (12/24 pulse) rectifier schemes are cost-effective methods for reducing line current harmonics in PWM motor drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations. In particular: excursion of DC-link voltage at no load; effect of pre-existing voltage distortion; impedance mismatches; unequal diode drops on rectifier current sharing; and performance are fully analyzed. Several corrective measures to improve the performance of 12/24-pulse rectifier systems are also discussed. Finally, experimental results on a 460 V, 60 Hz, 400 kVA commercial ASD, retrofitted with 12/24 pulse rectifier systems, are discussed in detail.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信