{"title":"锥面间隙局部放电活动的磁场扰动","authors":"D. Hepburn, B. Stewart, L. Dissado, J. Fothergill","doi":"10.1109/EEIC.2007.4562606","DOIUrl":null,"url":null,"abstract":"This paper presents initial partial discharge results for a simple cone-plane gap geometry under applied high voltage when a DC magnetic field is present. Initial phase resolved Phi-q-n results show that the influence of a DC magnetic field as low as 70 mT appears to alter the distribution of the Phi-q-n patterns. This result is important in order to understand the physical PD degradation processes occurring in the presence of the magnetic field. The extent and nature of changes within Phi-q-n patterns when a magnetic field is present will also be discussed as these patterns are often used for the assessment of partial discharge source types and insulation diagnosis.","PeriodicalId":152045,"journal":{"name":"2007 Electrical Insulation Conference and Electrical Manufacturing Expo","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Magnetic field disturbance of partial discharge activity in a cone-plane gap\",\"authors\":\"D. Hepburn, B. Stewart, L. Dissado, J. Fothergill\",\"doi\":\"10.1109/EEIC.2007.4562606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents initial partial discharge results for a simple cone-plane gap geometry under applied high voltage when a DC magnetic field is present. Initial phase resolved Phi-q-n results show that the influence of a DC magnetic field as low as 70 mT appears to alter the distribution of the Phi-q-n patterns. This result is important in order to understand the physical PD degradation processes occurring in the presence of the magnetic field. The extent and nature of changes within Phi-q-n patterns when a magnetic field is present will also be discussed as these patterns are often used for the assessment of partial discharge source types and insulation diagnosis.\",\"PeriodicalId\":152045,\"journal\":{\"name\":\"2007 Electrical Insulation Conference and Electrical Manufacturing Expo\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Electrical Insulation Conference and Electrical Manufacturing Expo\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEIC.2007.4562606\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Electrical Insulation Conference and Electrical Manufacturing Expo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2007.4562606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic field disturbance of partial discharge activity in a cone-plane gap
This paper presents initial partial discharge results for a simple cone-plane gap geometry under applied high voltage when a DC magnetic field is present. Initial phase resolved Phi-q-n results show that the influence of a DC magnetic field as low as 70 mT appears to alter the distribution of the Phi-q-n patterns. This result is important in order to understand the physical PD degradation processes occurring in the presence of the magnetic field. The extent and nature of changes within Phi-q-n patterns when a magnetic field is present will also be discussed as these patterns are often used for the assessment of partial discharge source types and insulation diagnosis.