基于esp32的物联网室内温湿度控制器原型

N. Mubarakah, Soeharwinto, Farhan Iddha
{"title":"基于esp32的物联网室内温湿度控制器原型","authors":"N. Mubarakah, Soeharwinto, Farhan Iddha","doi":"10.1109/ELTICOM57747.2022.10038085","DOIUrl":null,"url":null,"abstract":"This research was conducted to design a room air humidity and temperature control device to complement the features of an economical air conditioner (AC), which can automatically regulate humidity and temperature. So that the ideal level of humidity and temperature is achieved under the ministry of health’s provisions on comfort and air quality in the room, namely 40-60% Relative Humidity (RH) and 18-26 oC. To realize this, the AM2301 sensor is used to read the temperature and humidity in the room. Then the readings from the AM2301 sensor will be processed by ESP32 and then displayed on the OLED display and in the Blynk application, with infra-red LED as an AC controller and ultrasonic mist maker as a room humidity tool. Based on the results of the tests, this design has succeeded in becoming an additional feature of economics that lacks the features of air comfort and health. It is time to reach the ideal humidity level of 40-60% RH on average within 1 hour and 16 minutes.","PeriodicalId":406626,"journal":{"name":"2022 6th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prototype An ESP32-Based Room Humidity and Temperature Controller With IoT\",\"authors\":\"N. Mubarakah, Soeharwinto, Farhan Iddha\",\"doi\":\"10.1109/ELTICOM57747.2022.10038085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research was conducted to design a room air humidity and temperature control device to complement the features of an economical air conditioner (AC), which can automatically regulate humidity and temperature. So that the ideal level of humidity and temperature is achieved under the ministry of health’s provisions on comfort and air quality in the room, namely 40-60% Relative Humidity (RH) and 18-26 oC. To realize this, the AM2301 sensor is used to read the temperature and humidity in the room. Then the readings from the AM2301 sensor will be processed by ESP32 and then displayed on the OLED display and in the Blynk application, with infra-red LED as an AC controller and ultrasonic mist maker as a room humidity tool. Based on the results of the tests, this design has succeeded in becoming an additional feature of economics that lacks the features of air comfort and health. It is time to reach the ideal humidity level of 40-60% RH on average within 1 hour and 16 minutes.\",\"PeriodicalId\":406626,\"journal\":{\"name\":\"2022 6th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 6th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELTICOM57747.2022.10038085\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 6th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELTICOM57747.2022.10038085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究设计了一种室内空气温湿度控制装置,以补充经济型空调自动调节湿度和温度的特点。因此,在卫生部关于室内舒适和空气质量的规定下,达到理想的湿度和温度水平,即40-60%相对湿度(RH)和18-26℃。为了实现这一点,使用AM2301传感器读取房间内的温度和湿度。然后,来自AM2301传感器的读数将由ESP32进行处理,然后显示在OLED显示屏和Blynk应用程序中,红外LED作为交流控制器,超声波制雾器作为室内湿度工具。根据测试结果,这种设计已经成功地成为缺乏空气舒适和健康特征的额外经济特征。在1小时16分钟内达到40-60% RH的理想湿度水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prototype An ESP32-Based Room Humidity and Temperature Controller With IoT
This research was conducted to design a room air humidity and temperature control device to complement the features of an economical air conditioner (AC), which can automatically regulate humidity and temperature. So that the ideal level of humidity and temperature is achieved under the ministry of health’s provisions on comfort and air quality in the room, namely 40-60% Relative Humidity (RH) and 18-26 oC. To realize this, the AM2301 sensor is used to read the temperature and humidity in the room. Then the readings from the AM2301 sensor will be processed by ESP32 and then displayed on the OLED display and in the Blynk application, with infra-red LED as an AC controller and ultrasonic mist maker as a room humidity tool. Based on the results of the tests, this design has succeeded in becoming an additional feature of economics that lacks the features of air comfort and health. It is time to reach the ideal humidity level of 40-60% RH on average within 1 hour and 16 minutes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信