{"title":"CPAP氧浓度及流量的设计","authors":"A. Putra, T. Indrato, L. Soetjiatie","doi":"10.35882/JEEEMI.V1I1.2","DOIUrl":null,"url":null,"abstract":"Measuring oxygen concentration and measuring the flow of oxygen is a tool used to measure the percentage of oxygen content and oxygen flow rate in CPAP. This tool uses the OCS-03F sensor, with Arduino NANO processors then displayed on the 2X16 character LCD. Measuring the percentage of oxygen content and oxygen flow rate is carried out on CPAP for 5 measurements. The research and manufacture of this module uses the Pre-experimental method with the After Only Design design, which examines the \"Oxygen Analyzer\", which results in measurements compared to the traced tools to obtain high accuracy values. Based on the results of measurements on the CPAP tool at Dr. Soetomo Surabaya Hospital with oxygen level settings of 21%, 30%, 40%, 50% 60%, 70%, 80%, 90%, 100% while setting the oxygen measurement rate 1L/m, 2L /m, 3L/m, 4L/m, 5L/m, 6L/m, 7L//m, 8L/m, 9L/m 10L/m. Each measurement was carried out 5 times. For the measurement of oxygen levels the biggest error value is 5% and the smallest -0,06% while for the measurement of oxygen flow rate the biggest error value is 4% and the smallest is 0%. Based on the results of the analysis of the manufacture of oxygen levels and oxygen flow rates, it can be concluded that the manufacture of oxygen concentration measuring instruments and oxygen flow rate can work well.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"313 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Design of Oxygen Concentration and Flowrate in CPAP\",\"authors\":\"A. Putra, T. Indrato, L. Soetjiatie\",\"doi\":\"10.35882/JEEEMI.V1I1.2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measuring oxygen concentration and measuring the flow of oxygen is a tool used to measure the percentage of oxygen content and oxygen flow rate in CPAP. This tool uses the OCS-03F sensor, with Arduino NANO processors then displayed on the 2X16 character LCD. Measuring the percentage of oxygen content and oxygen flow rate is carried out on CPAP for 5 measurements. The research and manufacture of this module uses the Pre-experimental method with the After Only Design design, which examines the \\\"Oxygen Analyzer\\\", which results in measurements compared to the traced tools to obtain high accuracy values. Based on the results of measurements on the CPAP tool at Dr. Soetomo Surabaya Hospital with oxygen level settings of 21%, 30%, 40%, 50% 60%, 70%, 80%, 90%, 100% while setting the oxygen measurement rate 1L/m, 2L /m, 3L/m, 4L/m, 5L/m, 6L/m, 7L//m, 8L/m, 9L/m 10L/m. Each measurement was carried out 5 times. For the measurement of oxygen levels the biggest error value is 5% and the smallest -0,06% while for the measurement of oxygen flow rate the biggest error value is 4% and the smallest is 0%. Based on the results of the analysis of the manufacture of oxygen levels and oxygen flow rates, it can be concluded that the manufacture of oxygen concentration measuring instruments and oxygen flow rate can work well.\",\"PeriodicalId\":369032,\"journal\":{\"name\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"volume\":\"313 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35882/JEEEMI.V1I1.2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35882/JEEEMI.V1I1.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
测氧浓度和测氧流量是CPAP中测量氧含量百分比和氧流量的工具。该工具使用OCS-03F传感器,然后在2X16字符LCD上显示Arduino NANO处理器。在CPAP上进行了5次氧含量百分比和氧流量的测量。该模块的研究和制造采用了预实验方法和After Only Design设计,该设计检查了“氧气分析仪”,结果测量与跟踪工具进行比较,以获得高精度值。根据suetomo Surabaya医生医院CPAP工具的测量结果,氧气水平设置为21%,30%,40%,50%,60%,70%,80%,90%,100%,同时设置氧气测量率1L/m, 2L /m, 3L/m, 4L/m, 5L/m, 6L/m, 7L/ m, 8L/m, 9L/m 10L/m。每次测量5次。测量氧含量时,最大误差值为5%,最小误差值为- 0.06%;测量氧流量时,最大误差值为4%,最小误差值为0%。根据对氧浓度和氧流量的制造结果分析,可以得出制造的氧浓度测量仪和氧流量可以很好地工作。
The Design of Oxygen Concentration and Flowrate in CPAP
Measuring oxygen concentration and measuring the flow of oxygen is a tool used to measure the percentage of oxygen content and oxygen flow rate in CPAP. This tool uses the OCS-03F sensor, with Arduino NANO processors then displayed on the 2X16 character LCD. Measuring the percentage of oxygen content and oxygen flow rate is carried out on CPAP for 5 measurements. The research and manufacture of this module uses the Pre-experimental method with the After Only Design design, which examines the "Oxygen Analyzer", which results in measurements compared to the traced tools to obtain high accuracy values. Based on the results of measurements on the CPAP tool at Dr. Soetomo Surabaya Hospital with oxygen level settings of 21%, 30%, 40%, 50% 60%, 70%, 80%, 90%, 100% while setting the oxygen measurement rate 1L/m, 2L /m, 3L/m, 4L/m, 5L/m, 6L/m, 7L//m, 8L/m, 9L/m 10L/m. Each measurement was carried out 5 times. For the measurement of oxygen levels the biggest error value is 5% and the smallest -0,06% while for the measurement of oxygen flow rate the biggest error value is 4% and the smallest is 0%. Based on the results of the analysis of the manufacture of oxygen levels and oxygen flow rates, it can be concluded that the manufacture of oxygen concentration measuring instruments and oxygen flow rate can work well.