Z. Ben-Hur, D. Alon, Or Berebi, Ravish Mehra, B. Rafaely
{"title":"基于双侧立体声的双耳再现","authors":"Z. Ben-Hur, D. Alon, Or Berebi, Ravish Mehra, B. Rafaely","doi":"10.5772/intechopen.100402","DOIUrl":null,"url":null,"abstract":"Binaural reproduction of high-quality spatial sound has gained considerable interest with the recent technology developments in virtual and augmented reality. The reproduction of binaural signals in the Spherical-Harmonics (SH) domain using Ambisonics is now a well-established methodology, with flexible binaural processing realized using SH representations of the sound-field and the Head-Related Transfer Function (HRTF). However, in most practical cases, the binaural reproduction is order-limited, which introduces truncation errors that have a detrimental effect on the perception of the reproduced signals, mainly due to the truncation of the HRTF. Recently, it has been shown that manipulating the HRTF phase component, by ear-alignment, significantly reduces its effective SH order while preserving its phase information, which may be beneficial for alleviating the above detrimental effect. Incorporating the ear-aligned HRTF into the binaural reproduction process has been suggested by using Bilateral Ambisonics, which is an Ambisonics representation of the sound-field formulated at the two ears. While this method imposes challenges on acquiring the sound-field, and specifically, on applying head-rotations, it leads to a significant reduction in errors caused by the limited-order reproduction, which yields a substantial improvement in the perceived binaural reproduction quality even with first order SH.","PeriodicalId":178175,"journal":{"name":"Advances in Fundamental and Applied Research on Spatial Audio [Working Title]","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Binaural Reproduction Based on Bilateral Ambisonics\",\"authors\":\"Z. Ben-Hur, D. Alon, Or Berebi, Ravish Mehra, B. Rafaely\",\"doi\":\"10.5772/intechopen.100402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Binaural reproduction of high-quality spatial sound has gained considerable interest with the recent technology developments in virtual and augmented reality. The reproduction of binaural signals in the Spherical-Harmonics (SH) domain using Ambisonics is now a well-established methodology, with flexible binaural processing realized using SH representations of the sound-field and the Head-Related Transfer Function (HRTF). However, in most practical cases, the binaural reproduction is order-limited, which introduces truncation errors that have a detrimental effect on the perception of the reproduced signals, mainly due to the truncation of the HRTF. Recently, it has been shown that manipulating the HRTF phase component, by ear-alignment, significantly reduces its effective SH order while preserving its phase information, which may be beneficial for alleviating the above detrimental effect. Incorporating the ear-aligned HRTF into the binaural reproduction process has been suggested by using Bilateral Ambisonics, which is an Ambisonics representation of the sound-field formulated at the two ears. While this method imposes challenges on acquiring the sound-field, and specifically, on applying head-rotations, it leads to a significant reduction in errors caused by the limited-order reproduction, which yields a substantial improvement in the perceived binaural reproduction quality even with first order SH.\",\"PeriodicalId\":178175,\"journal\":{\"name\":\"Advances in Fundamental and Applied Research on Spatial Audio [Working Title]\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Fundamental and Applied Research on Spatial Audio [Working Title]\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5772/intechopen.100402\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Fundamental and Applied Research on Spatial Audio [Working Title]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5772/intechopen.100402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Binaural Reproduction Based on Bilateral Ambisonics
Binaural reproduction of high-quality spatial sound has gained considerable interest with the recent technology developments in virtual and augmented reality. The reproduction of binaural signals in the Spherical-Harmonics (SH) domain using Ambisonics is now a well-established methodology, with flexible binaural processing realized using SH representations of the sound-field and the Head-Related Transfer Function (HRTF). However, in most practical cases, the binaural reproduction is order-limited, which introduces truncation errors that have a detrimental effect on the perception of the reproduced signals, mainly due to the truncation of the HRTF. Recently, it has been shown that manipulating the HRTF phase component, by ear-alignment, significantly reduces its effective SH order while preserving its phase information, which may be beneficial for alleviating the above detrimental effect. Incorporating the ear-aligned HRTF into the binaural reproduction process has been suggested by using Bilateral Ambisonics, which is an Ambisonics representation of the sound-field formulated at the two ears. While this method imposes challenges on acquiring the sound-field, and specifically, on applying head-rotations, it leads to a significant reduction in errors caused by the limited-order reproduction, which yields a substantial improvement in the perceived binaural reproduction quality even with first order SH.