Xavi Oliva, J. Oliva, J. Oliva, H. Prasad, M. Rohrer
{"title":"氧化锆(Y-TZP)植牙体的骨整合:绵羊髋关节的组织学、组织形态学和去除扭矩研究","authors":"Xavi Oliva, J. Oliva, J. Oliva, H. Prasad, M. Rohrer","doi":"10.5005/JP-JOURNALS-10012-1093","DOIUrl":null,"url":null,"abstract":"Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric analysis, and the other four implants were used for removal torque test (RTQ). Results: The histological evaluation showed a direct bone to implant contact (BIC) with no signs of inflammatory or foreign body reaction. The histomorphometric analysis values ranged from 79.5 to 79.9% of BIC. The RTQ showed values ranging from 75 to 83 Ncm. Discussion: In this animal study, the biocompatibility of CeraRoot zirconia (Y-TZP) implants was demonstrated with the histologic observations of healthy bone tissue in direct contact with the zirconia (Y-TZP) implant surface. Moreover, the histomorphometric analysis and the RTQ confirmed a rigid fixation of the implant within the bone. Comparative studies with acid-etched titanium implants are needed to further evaluate the characteristics of CeraRoot zirconia dental implants.","PeriodicalId":303737,"journal":{"name":"International Journal of Oral Implantology and Clinical Research","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Osseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep\",\"authors\":\"Xavi Oliva, J. Oliva, J. Oliva, H. Prasad, M. Rohrer\",\"doi\":\"10.5005/JP-JOURNALS-10012-1093\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric analysis, and the other four implants were used for removal torque test (RTQ). Results: The histological evaluation showed a direct bone to implant contact (BIC) with no signs of inflammatory or foreign body reaction. The histomorphometric analysis values ranged from 79.5 to 79.9% of BIC. The RTQ showed values ranging from 75 to 83 Ncm. Discussion: In this animal study, the biocompatibility of CeraRoot zirconia (Y-TZP) implants was demonstrated with the histologic observations of healthy bone tissue in direct contact with the zirconia (Y-TZP) implant surface. Moreover, the histomorphometric analysis and the RTQ confirmed a rigid fixation of the implant within the bone. Comparative studies with acid-etched titanium implants are needed to further evaluate the characteristics of CeraRoot zirconia dental implants.\",\"PeriodicalId\":303737,\"journal\":{\"name\":\"International Journal of Oral Implantology and Clinical Research\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Oral Implantology and Clinical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/JP-JOURNALS-10012-1093\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral Implantology and Clinical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/JP-JOURNALS-10012-1093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Osseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep
Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric analysis, and the other four implants were used for removal torque test (RTQ). Results: The histological evaluation showed a direct bone to implant contact (BIC) with no signs of inflammatory or foreign body reaction. The histomorphometric analysis values ranged from 79.5 to 79.9% of BIC. The RTQ showed values ranging from 75 to 83 Ncm. Discussion: In this animal study, the biocompatibility of CeraRoot zirconia (Y-TZP) implants was demonstrated with the histologic observations of healthy bone tissue in direct contact with the zirconia (Y-TZP) implant surface. Moreover, the histomorphometric analysis and the RTQ confirmed a rigid fixation of the implant within the bone. Comparative studies with acid-etched titanium implants are needed to further evaluate the characteristics of CeraRoot zirconia dental implants.