H. Natalius, Med Physics, P. Lambert, L. Cruz, C. Bergeles, B. Eng
{"title":"用于玻璃体视网膜手术头部稳定的非轴对称并联机械臂","authors":"H. Natalius, Med Physics, P. Lambert, L. Cruz, C. Bergeles, B. Eng","doi":"10.31256/yi5od4a","DOIUrl":null,"url":null,"abstract":"Kingdom 0000-0002-9152-3194 Abstract —A non-axisymmetric parallel manipulator headrest design was previously proposed to counter patient head motion during ophthalmic surgery, and a non-motorized prototype was built. Custom linear actuators were designed, and installed to the headrest manipulator prototype in preparation for kinematic performance test. An inverse kinematic-based control algorithm was implemented, and initial kinematic testing was done. Finally, the future plans for the research are","PeriodicalId":447290,"journal":{"name":"UKRAS21 Conference: Robotics at home Proceedings","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Non-Axisymmetric Parallel Manipulator for Head Stabilisation in Vitreoretinal Surgery\",\"authors\":\"H. Natalius, Med Physics, P. Lambert, L. Cruz, C. Bergeles, B. Eng\",\"doi\":\"10.31256/yi5od4a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Kingdom 0000-0002-9152-3194 Abstract —A non-axisymmetric parallel manipulator headrest design was previously proposed to counter patient head motion during ophthalmic surgery, and a non-motorized prototype was built. Custom linear actuators were designed, and installed to the headrest manipulator prototype in preparation for kinematic performance test. An inverse kinematic-based control algorithm was implemented, and initial kinematic testing was done. Finally, the future plans for the research are\",\"PeriodicalId\":447290,\"journal\":{\"name\":\"UKRAS21 Conference: Robotics at home Proceedings\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"UKRAS21 Conference: Robotics at home Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31256/yi5od4a\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"UKRAS21 Conference: Robotics at home Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31256/yi5od4a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Non-Axisymmetric Parallel Manipulator for Head Stabilisation in Vitreoretinal Surgery
Kingdom 0000-0002-9152-3194 Abstract —A non-axisymmetric parallel manipulator headrest design was previously proposed to counter patient head motion during ophthalmic surgery, and a non-motorized prototype was built. Custom linear actuators were designed, and installed to the headrest manipulator prototype in preparation for kinematic performance test. An inverse kinematic-based control algorithm was implemented, and initial kinematic testing was done. Finally, the future plans for the research are