传感器位置移位对张力肌图参数的影响

Stefanie John, Nico Leon Stallmach, K. Witte
{"title":"传感器位置移位对张力肌图参数的影响","authors":"Stefanie John, Nico Leon Stallmach, K. Witte","doi":"10.55860/rpzl3362","DOIUrl":null,"url":null,"abstract":"Tensiomyography (TMG) is a non-invasive method to determine contractile parameters of skeletal muscles. Several methodological factors, however, might affect TMG results. The aim of this study was to investigate the effect of specific sensor position shifts on tensiomyographic parameters. 14 healthy males (age: 22.6 ± 1.2 years) participated in the study. TMG measurements were performed for rectus femoris (RF), gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) on five sensor positions. The original sensor position (OP) was the recommended position on the muscle belly while for the shifted positions, the sensor was displaced one centimetre medially, laterally, proximally, and distally. TMG parameters measured were maximum radial displacement (Dm) and contraction time (Tc). To investigate the effect of sensor position shift, repeated-measures ANOVAs were performed. The ANOVAs revealed significant differences across the five sensor positions for RF and GM. Posthoc analysis showed significant reductions in Dm by 10 % (p = .03) and in Tc by 12 % (p = .008) in the laterally shifted sensor position for RF. For GM, Dm was significantly reduced by 20 % (p = .038) in the medially displaced sensor position. The results suggest that incorrect sensor positioning has an impact on TMG parameters, especially when incorrectly positioned in the medial-lateral direction.","PeriodicalId":224249,"journal":{"name":"Scientific Journal of Sport and Performance","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The effect of sensor position shifts on tensiomyographic parameters\",\"authors\":\"Stefanie John, Nico Leon Stallmach, K. Witte\",\"doi\":\"10.55860/rpzl3362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tensiomyography (TMG) is a non-invasive method to determine contractile parameters of skeletal muscles. Several methodological factors, however, might affect TMG results. The aim of this study was to investigate the effect of specific sensor position shifts on tensiomyographic parameters. 14 healthy males (age: 22.6 ± 1.2 years) participated in the study. TMG measurements were performed for rectus femoris (RF), gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) on five sensor positions. The original sensor position (OP) was the recommended position on the muscle belly while for the shifted positions, the sensor was displaced one centimetre medially, laterally, proximally, and distally. TMG parameters measured were maximum radial displacement (Dm) and contraction time (Tc). To investigate the effect of sensor position shift, repeated-measures ANOVAs were performed. The ANOVAs revealed significant differences across the five sensor positions for RF and GM. Posthoc analysis showed significant reductions in Dm by 10 % (p = .03) and in Tc by 12 % (p = .008) in the laterally shifted sensor position for RF. For GM, Dm was significantly reduced by 20 % (p = .038) in the medially displaced sensor position. The results suggest that incorrect sensor positioning has an impact on TMG parameters, especially when incorrectly positioned in the medial-lateral direction.\",\"PeriodicalId\":224249,\"journal\":{\"name\":\"Scientific Journal of Sport and Performance\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scientific Journal of Sport and Performance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55860/rpzl3362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Journal of Sport and Performance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55860/rpzl3362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

张力肌图(TMG)是一种测定骨骼肌收缩参数的无创方法。然而,几个方法学因素可能会影响TMG的结果。本研究的目的是研究特定传感器位置移位对张力肌图参数的影响。14名健康男性(年龄:22.6±1.2岁)参与研究。在5个传感器位置对股直肌(RF)、腓肠肌内侧(GM)和腓肠肌外侧(GL)进行TMG测量。原始传感器位置(OP)是肌肉腹部的推荐位置,而对于移位位置,传感器在内侧,外侧,近端和远端移位1厘米。测量的TMG参数为最大径向位移(Dm)和收缩时间(Tc)。为了研究传感器位置移位的影响,进行了重复测量方差分析。方差分析显示RF和GM的五个传感器位置之间存在显著差异。后置分析显示,RF的横向移位传感器位置显著降低Dm 10% (p = 0.03), Tc降低12% (p = 0.008)。对于GM,在传感器的中间位置,Dm显著降低了20% (p = 0.038)。结果表明,不正确的传感器定位对TMG参数有影响,特别是当不正确地定位在内侧-外侧方向时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of sensor position shifts on tensiomyographic parameters
Tensiomyography (TMG) is a non-invasive method to determine contractile parameters of skeletal muscles. Several methodological factors, however, might affect TMG results. The aim of this study was to investigate the effect of specific sensor position shifts on tensiomyographic parameters. 14 healthy males (age: 22.6 ± 1.2 years) participated in the study. TMG measurements were performed for rectus femoris (RF), gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) on five sensor positions. The original sensor position (OP) was the recommended position on the muscle belly while for the shifted positions, the sensor was displaced one centimetre medially, laterally, proximally, and distally. TMG parameters measured were maximum radial displacement (Dm) and contraction time (Tc). To investigate the effect of sensor position shift, repeated-measures ANOVAs were performed. The ANOVAs revealed significant differences across the five sensor positions for RF and GM. Posthoc analysis showed significant reductions in Dm by 10 % (p = .03) and in Tc by 12 % (p = .008) in the laterally shifted sensor position for RF. For GM, Dm was significantly reduced by 20 % (p = .038) in the medially displaced sensor position. The results suggest that incorrect sensor positioning has an impact on TMG parameters, especially when incorrectly positioned in the medial-lateral direction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信