握力与肌肉厚度关系的初步研究

Xingchen Yang, Yuefeng Li, Yinfeng Fang, Honghai Liu
{"title":"握力与肌肉厚度关系的初步研究","authors":"Xingchen Yang, Yuefeng Li, Yinfeng Fang, Honghai Liu","doi":"10.1109/NER.2017.8008306","DOIUrl":null,"url":null,"abstract":"In this study, we propose a novel method to explore the relationship between grip force and forearm muscle thickness during isometric contraction. One-directional ultrasound was used to detect the depth of muscle-bone interface. By tracking the movement of this interface, the change of muscle thickness can be calculated. A dynamometer was used to measure force. Three able-bodied subjects were asked to gradually increase grasping force from 0% to 40% maximum voluntary contraction (MVC) and decrease grasping force from 40% to 0% MVC following the guiding patterns on the screen, 4 channels of one-directional ultrasound signals on the forearm were recorded in the meanwhile. The relationship between extensor digitorum muscle and grip force was analyzed and the results showed that the relationship between this muscle and grip force can be represented with two exponential functions, with averaged R2 value of 0.982. And the existence of hysteresis in the muscle thickness-force relationship is discovered. These relationships have potential importance on grip force estimation.","PeriodicalId":142883,"journal":{"name":"2017 8th International IEEE/EMBS Conference on Neural Engineering (NER)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A preliminary study on the relationship between grip force and muscle thickness\",\"authors\":\"Xingchen Yang, Yuefeng Li, Yinfeng Fang, Honghai Liu\",\"doi\":\"10.1109/NER.2017.8008306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we propose a novel method to explore the relationship between grip force and forearm muscle thickness during isometric contraction. One-directional ultrasound was used to detect the depth of muscle-bone interface. By tracking the movement of this interface, the change of muscle thickness can be calculated. A dynamometer was used to measure force. Three able-bodied subjects were asked to gradually increase grasping force from 0% to 40% maximum voluntary contraction (MVC) and decrease grasping force from 40% to 0% MVC following the guiding patterns on the screen, 4 channels of one-directional ultrasound signals on the forearm were recorded in the meanwhile. The relationship between extensor digitorum muscle and grip force was analyzed and the results showed that the relationship between this muscle and grip force can be represented with two exponential functions, with averaged R2 value of 0.982. And the existence of hysteresis in the muscle thickness-force relationship is discovered. These relationships have potential importance on grip force estimation.\",\"PeriodicalId\":142883,\"journal\":{\"name\":\"2017 8th International IEEE/EMBS Conference on Neural Engineering (NER)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 8th International IEEE/EMBS Conference on Neural Engineering (NER)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NER.2017.8008306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 8th International IEEE/EMBS Conference on Neural Engineering (NER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NER.2017.8008306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在这项研究中,我们提出了一种新的方法来探索握力与前臂肌肉厚度在等距收缩过程中的关系。采用单向超声检测肌-骨界面深度。通过跟踪该界面的运动,可以计算出肌肉厚度的变化。用测功机测量力。3名身体健全的被试按照屏幕上的引导模式,逐渐将最大自主收缩力(MVC)从0%增加到40%,将最大自主收缩力(MVC)从40%减少到0%,同时记录前臂上4个单向超声信号通道。分析了指伸肌与握力的关系,结果表明,指伸肌与握力的关系可以用2个指数函数表示,平均R2值为0.982。发现了肌厚-力关系中存在滞回现象。这些关系对握力估计具有潜在的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A preliminary study on the relationship between grip force and muscle thickness
In this study, we propose a novel method to explore the relationship between grip force and forearm muscle thickness during isometric contraction. One-directional ultrasound was used to detect the depth of muscle-bone interface. By tracking the movement of this interface, the change of muscle thickness can be calculated. A dynamometer was used to measure force. Three able-bodied subjects were asked to gradually increase grasping force from 0% to 40% maximum voluntary contraction (MVC) and decrease grasping force from 40% to 0% MVC following the guiding patterns on the screen, 4 channels of one-directional ultrasound signals on the forearm were recorded in the meanwhile. The relationship between extensor digitorum muscle and grip force was analyzed and the results showed that the relationship between this muscle and grip force can be represented with two exponential functions, with averaged R2 value of 0.982. And the existence of hysteresis in the muscle thickness-force relationship is discovered. These relationships have potential importance on grip force estimation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信