Seokwon Joo, Y. Jeon
{"title":"粉碎性骨折用桡骨钢板和重叠技术进行肋骨固定","authors":"Seokwon Joo, Y. Jeon","doi":"10.24184/TIP.2018.3.1.28","DOIUrl":null,"url":null,"abstract":"A 49-year-old male with sustained multiple comminuted right rib (3rd–9th) fractures, right pneumothorax, and a flail chest was referred to our hospital with complaints of severe pain. He previously underwent closed thoracostomy in the right thoracic cavity. Rib fixation was performed after 4 days. On evaluation, comminuted fractures of the 4–8th right ribs were detected. We followed a conventional method of using an 8or 6-hole-plate (MatrixRIB; DepuySynthes, USA) and an 8or 4-hole-plate (RibFix BluTM; DepuySynthes) for his rib fixation. The fourth rib was fixed using an 8-hole-plate (MatrixRIB). However, the distance of the intact portion on the 5–7th ribs was too long to be successfully managed using a conventionally used plate. Therefore, 8-hole-plates (Small Fragment Locking Compression Plate; DepuySynthes), which are usually employed for radius fixation, were used on these ribs. The 8 rib was fixed with an overlapping method with two flexible 4-hole-plates (RibFix BluTM) and a longer screw, considering the anatomy of the comminuted fractures (Fig. 1.). The patient was extubated the day after the operation and was transferred to the general ward on the second day after the operation. The plates were intact even on 40th postoperative day.","PeriodicalId":224399,"journal":{"name":"Trauma Image and Procedure","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rib fixation with a plate for radius and overlapping technique in comminuted fractures\",\"authors\":\"Seokwon Joo, Y. Jeon\",\"doi\":\"10.24184/TIP.2018.3.1.28\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 49-year-old male with sustained multiple comminuted right rib (3rd–9th) fractures, right pneumothorax, and a flail chest was referred to our hospital with complaints of severe pain. He previously underwent closed thoracostomy in the right thoracic cavity. Rib fixation was performed after 4 days. On evaluation, comminuted fractures of the 4–8th right ribs were detected. We followed a conventional method of using an 8or 6-hole-plate (MatrixRIB; DepuySynthes, USA) and an 8or 4-hole-plate (RibFix BluTM; DepuySynthes) for his rib fixation. The fourth rib was fixed using an 8-hole-plate (MatrixRIB). However, the distance of the intact portion on the 5–7th ribs was too long to be successfully managed using a conventionally used plate. Therefore, 8-hole-plates (Small Fragment Locking Compression Plate; DepuySynthes), which are usually employed for radius fixation, were used on these ribs. The 8 rib was fixed with an overlapping method with two flexible 4-hole-plates (RibFix BluTM) and a longer screw, considering the anatomy of the comminuted fractures (Fig. 1.). The patient was extubated the day after the operation and was transferred to the general ward on the second day after the operation. The plates were intact even on 40th postoperative day.\",\"PeriodicalId\":224399,\"journal\":{\"name\":\"Trauma Image and Procedure\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trauma Image and Procedure\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24184/TIP.2018.3.1.28\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Image and Procedure","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24184/TIP.2018.3.1.28","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一名49岁男性,持续多处右侧肋骨粉碎性骨折(第3 - 9节),右侧气胸,连枷胸,主诉剧烈疼痛转介至我院。他之前在右胸腔做过闭合性开胸手术。4天后进行肋骨固定。在评估中,发现第4 - 8根右肋骨粉碎性骨折。我们采用常规方法使用8或6孔钢板(MatrixRIB;DepuySynthes, USA)和一个8孔或4孔板(RibFix BluTM;DepuySynthes)为他的肋骨固定。采用8孔钢板(MatrixRIB)固定第四根肋骨。然而,第5 - 7根肋骨上完整部分的距离太长,无法使用传统的钢板成功处理。因此,8孔钢板(小碎片锁定压缩板;DepuySynthes)通常用于桡骨固定,在这些肋骨上使用。考虑到粉碎性骨折的解剖结构,采用两个柔性4孔钢板(RibFix BluTM)和一枚较长的螺钉重叠固定8肋(图1)。术后第1天拔管,术后第2天转至普通病房。即使在术后第40天,钢板仍完好无损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rib fixation with a plate for radius and overlapping technique in comminuted fractures
A 49-year-old male with sustained multiple comminuted right rib (3rd–9th) fractures, right pneumothorax, and a flail chest was referred to our hospital with complaints of severe pain. He previously underwent closed thoracostomy in the right thoracic cavity. Rib fixation was performed after 4 days. On evaluation, comminuted fractures of the 4–8th right ribs were detected. We followed a conventional method of using an 8or 6-hole-plate (MatrixRIB; DepuySynthes, USA) and an 8or 4-hole-plate (RibFix BluTM; DepuySynthes) for his rib fixation. The fourth rib was fixed using an 8-hole-plate (MatrixRIB). However, the distance of the intact portion on the 5–7th ribs was too long to be successfully managed using a conventionally used plate. Therefore, 8-hole-plates (Small Fragment Locking Compression Plate; DepuySynthes), which are usually employed for radius fixation, were used on these ribs. The 8 rib was fixed with an overlapping method with two flexible 4-hole-plates (RibFix BluTM) and a longer screw, considering the anatomy of the comminuted fractures (Fig. 1.). The patient was extubated the day after the operation and was transferred to the general ward on the second day after the operation. The plates were intact even on 40th postoperative day.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信