D. Nikolić, M. Negnevitsky, M. de Groot, S. Gamble, J. Forbes, M. Ross
{"title":"快速需求响应作为隔离电力系统中可再生能源高渗透的使能技术","authors":"D. Nikolić, M. Negnevitsky, M. de Groot, S. Gamble, J. Forbes, M. Ross","doi":"10.1109/PESGM.2014.6939282","DOIUrl":null,"url":null,"abstract":"Isolated power systems (IPSs) up to 20MW capacity are often based on diesel generators. Due to the high cost of diesel fuel supply, as well as environmental concerns, IPSs should ideally include a large proportion of renewable energy generation. We report on the implementation of a simple, finegrained and fast demand response (DR) technology to enable high wind penetration in an IPS. This solution is based on centralized two-way communication and control of residential and commercial loads. DR can be dispatched and confirmed within 1 second. The technology has been installed and successfully tested in an IPS on an island in Australia.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"183 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Fast demand response as an enabling technology for high renewable energy penetration in isolated power systems\",\"authors\":\"D. Nikolić, M. Negnevitsky, M. de Groot, S. Gamble, J. Forbes, M. Ross\",\"doi\":\"10.1109/PESGM.2014.6939282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Isolated power systems (IPSs) up to 20MW capacity are often based on diesel generators. Due to the high cost of diesel fuel supply, as well as environmental concerns, IPSs should ideally include a large proportion of renewable energy generation. We report on the implementation of a simple, finegrained and fast demand response (DR) technology to enable high wind penetration in an IPS. This solution is based on centralized two-way communication and control of residential and commercial loads. DR can be dispatched and confirmed within 1 second. The technology has been installed and successfully tested in an IPS on an island in Australia.\",\"PeriodicalId\":149134,\"journal\":{\"name\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"volume\":\"183 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2014.6939282\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fast demand response as an enabling technology for high renewable energy penetration in isolated power systems
Isolated power systems (IPSs) up to 20MW capacity are often based on diesel generators. Due to the high cost of diesel fuel supply, as well as environmental concerns, IPSs should ideally include a large proportion of renewable energy generation. We report on the implementation of a simple, finegrained and fast demand response (DR) technology to enable high wind penetration in an IPS. This solution is based on centralized two-way communication and control of residential and commercial loads. DR can be dispatched and confirmed within 1 second. The technology has been installed and successfully tested in an IPS on an island in Australia.