{"title":"用热电离检测器对低压开关柜进行热监测","authors":"Amjad Hussain, M. Shafiq, M. Lehtonen","doi":"10.1109/RTUCON.2016.7763142","DOIUrl":null,"url":null,"abstract":"Reliable operation of the switchgear is essential for delivery of electric power to the end users. Poor connections and insulation degradation are the two major causes of arc-flash in the switchgear. This paper evaluates the non-intrusive measurement and performance of thermal ionization detector (TID) in the low voltage (LV) air insulated switchgear. The sensitivity analysis of the sensor is done in comparison with thermocouples. Experimental investigation is performed in a climate controlled chamber where bus bars having poor joints are installed. Useful deductions based on measured results, have been discussed in this paper. This particular type of study is nonexistent in the literature. So, it will be remarkably helpful for the researcher and engineers working in the online condition monitoring area.","PeriodicalId":102691,"journal":{"name":"2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Thermal monitoring of low voltage switchgear using thermal ionization detector\",\"authors\":\"Amjad Hussain, M. Shafiq, M. Lehtonen\",\"doi\":\"10.1109/RTUCON.2016.7763142\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reliable operation of the switchgear is essential for delivery of electric power to the end users. Poor connections and insulation degradation are the two major causes of arc-flash in the switchgear. This paper evaluates the non-intrusive measurement and performance of thermal ionization detector (TID) in the low voltage (LV) air insulated switchgear. The sensitivity analysis of the sensor is done in comparison with thermocouples. Experimental investigation is performed in a climate controlled chamber where bus bars having poor joints are installed. Useful deductions based on measured results, have been discussed in this paper. This particular type of study is nonexistent in the literature. So, it will be remarkably helpful for the researcher and engineers working in the online condition monitoring area.\",\"PeriodicalId\":102691,\"journal\":{\"name\":\"2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTUCON.2016.7763142\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON.2016.7763142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

开关柜的可靠运行对向最终用户输送电力至关重要。接线不良和绝缘劣化是引起开关柜闪弧的两大原因。本文对低压空气绝缘开关柜中热电离检测器(TID)的非侵入式测量及其性能进行了评价。并与热电偶进行了灵敏度分析。实验调查是在一个气候控制的室内进行的,其中安装了接头较差的母线。本文讨论了基于实测结果的有用的推导。这种特殊的研究在文献中是不存在的。因此,对于从事在线状态监测领域的研究人员和工程技术人员具有重要的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal monitoring of low voltage switchgear using thermal ionization detector
Reliable operation of the switchgear is essential for delivery of electric power to the end users. Poor connections and insulation degradation are the two major causes of arc-flash in the switchgear. This paper evaluates the non-intrusive measurement and performance of thermal ionization detector (TID) in the low voltage (LV) air insulated switchgear. The sensitivity analysis of the sensor is done in comparison with thermocouples. Experimental investigation is performed in a climate controlled chamber where bus bars having poor joints are installed. Useful deductions based on measured results, have been discussed in this paper. This particular type of study is nonexistent in the literature. So, it will be remarkably helpful for the researcher and engineers working in the online condition monitoring area.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信