Bao-Ren Huang, Chia-Han Chang, R. Fang, Chun-Long Wang
{"title":"采用电感和电容补偿的弯曲差动传输线","authors":"Bao-Ren Huang, Chia-Han Chang, R. Fang, Chun-Long Wang","doi":"10.1109/SAPIW.2015.7237391","DOIUrl":null,"url":null,"abstract":"In this paper, a bended differential transmission line using the compensation inductance and capacitance is proposed. The bended differential transmission line using the compensation inductance and capacitance can greatly reduce the TDT common-mode noise from 0.056 V to 0.019 V as compared with the bended differential transmission line using the right-angle bend. In order to verify the simulation results, measurement is done in the time domain where the measurement results are in good agreement with the simulation results.","PeriodicalId":231437,"journal":{"name":"2015 IEEE 19th Workshop on Signal and Power Integrity (SPI)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bended differential transmission line using compensation inductance and capacitance\",\"authors\":\"Bao-Ren Huang, Chia-Han Chang, R. Fang, Chun-Long Wang\",\"doi\":\"10.1109/SAPIW.2015.7237391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a bended differential transmission line using the compensation inductance and capacitance is proposed. The bended differential transmission line using the compensation inductance and capacitance can greatly reduce the TDT common-mode noise from 0.056 V to 0.019 V as compared with the bended differential transmission line using the right-angle bend. In order to verify the simulation results, measurement is done in the time domain where the measurement results are in good agreement with the simulation results.\",\"PeriodicalId\":231437,\"journal\":{\"name\":\"2015 IEEE 19th Workshop on Signal and Power Integrity (SPI)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 19th Workshop on Signal and Power Integrity (SPI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SAPIW.2015.7237391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 19th Workshop on Signal and Power Integrity (SPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAPIW.2015.7237391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Bended differential transmission line using compensation inductance and capacitance
In this paper, a bended differential transmission line using the compensation inductance and capacitance is proposed. The bended differential transmission line using the compensation inductance and capacitance can greatly reduce the TDT common-mode noise from 0.056 V to 0.019 V as compared with the bended differential transmission line using the right-angle bend. In order to verify the simulation results, measurement is done in the time domain where the measurement results are in good agreement with the simulation results.