用于UPS的电流源逆变器

S. Dewan, M. Agu
{"title":"用于UPS的电流源逆变器","authors":"S. Dewan, M. Agu","doi":"10.1109/INTLEC.1979.4793657","DOIUrl":null,"url":null,"abstract":"An uninterruptible power supply (UPS) system using a current source inverter is proposed. A single phase and a three phase load commutated current source inverter suitable for this UPS system is presented. The load commutation is achieved by selecting the output filter to maintain a net leading power factor at the inverter output over the operating load range. A steady state analysis of the inverter power circuits is given. The analysis is based on using the harmonic series of the inverter output current to obtain the circuit voltages and currents. The theoretical results presented in this paper are verified on experimental models for both the single phase and the three phase inverters.","PeriodicalId":177302,"journal":{"name":"INTELEC - 1979 International Telecommunications Energy Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Current Source Inverter for UPS\",\"authors\":\"S. Dewan, M. Agu\",\"doi\":\"10.1109/INTLEC.1979.4793657\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An uninterruptible power supply (UPS) system using a current source inverter is proposed. A single phase and a three phase load commutated current source inverter suitable for this UPS system is presented. The load commutation is achieved by selecting the output filter to maintain a net leading power factor at the inverter output over the operating load range. A steady state analysis of the inverter power circuits is given. The analysis is based on using the harmonic series of the inverter output current to obtain the circuit voltages and currents. The theoretical results presented in this paper are verified on experimental models for both the single phase and the three phase inverters.\",\"PeriodicalId\":177302,\"journal\":{\"name\":\"INTELEC - 1979 International Telecommunications Energy Conference\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC - 1979 International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1979.4793657\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC - 1979 International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1979.4793657","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种采用电流源逆变器的不间断电源系统。介绍了适用于该UPS系统的单相和三相负载换相电流源逆变器。负载换相是通过选择输出滤波器在工作负载范围内保持逆变器输出的净领先功率因数来实现的。给出了逆变电源电路的稳态分析。分析的基础是利用逆变器输出电流的谐波级数得到电路的电压和电流。本文的理论结果在单相和三相逆变器的实验模型上得到了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Current Source Inverter for UPS
An uninterruptible power supply (UPS) system using a current source inverter is proposed. A single phase and a three phase load commutated current source inverter suitable for this UPS system is presented. The load commutation is achieved by selecting the output filter to maintain a net leading power factor at the inverter output over the operating load range. A steady state analysis of the inverter power circuits is given. The analysis is based on using the harmonic series of the inverter output current to obtain the circuit voltages and currents. The theoretical results presented in this paper are verified on experimental models for both the single phase and the three phase inverters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信