{"title":"全消声室的校正及与OATS测量值的相关性","authors":"R. McConnell, C. Vitek","doi":"10.1109/ISEMC.1996.561215","DOIUrl":null,"url":null,"abstract":"Fully anechoic rooms may gradually replace open area test sites as the preferred type of testing facility for the measurement of radiated emissions. The fully anechoic room offers several advantages over the open area test site. Immunity to high ambient signal levels, the capability of being located in metropolitan areas close to the customer base, more uniform field over a larger area a reduction in test time since there is no need to scan the receiving antenna in height, and the capability of being used for both emissions and susceptibility testing. Measurements of site attenuation in a fully anechoic room show excellent correlation with the mathematical model for normalized site attenuation in free space. The mathematical model and the measurement results are presented.","PeriodicalId":296175,"journal":{"name":"Proceedings of Symposium on Electromagnetic Compatibility","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Calibration of fully anechoic rooms and correlation with OATS measurements\",\"authors\":\"R. McConnell, C. Vitek\",\"doi\":\"10.1109/ISEMC.1996.561215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fully anechoic rooms may gradually replace open area test sites as the preferred type of testing facility for the measurement of radiated emissions. The fully anechoic room offers several advantages over the open area test site. Immunity to high ambient signal levels, the capability of being located in metropolitan areas close to the customer base, more uniform field over a larger area a reduction in test time since there is no need to scan the receiving antenna in height, and the capability of being used for both emissions and susceptibility testing. Measurements of site attenuation in a fully anechoic room show excellent correlation with the mathematical model for normalized site attenuation in free space. The mathematical model and the measurement results are presented.\",\"PeriodicalId\":296175,\"journal\":{\"name\":\"Proceedings of Symposium on Electromagnetic Compatibility\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1996.561215\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1996.561215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

完全消声室可能逐渐取代开放区域试验场,成为测量辐射发射的首选测试设施。完全消声室比开放区域试验场有几个优势。对高环境信号水平的抗扰性,位于靠近客户群的大都市地区的能力,在更大的区域内更均匀的场,减少了测试时间,因为不需要在高度上扫描接收天线,并且能够用于发射和敏感性测试。在完全消声室中测量的站点衰减与自由空间中归一化站点衰减的数学模型具有良好的相关性。给出了数学模型和测量结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calibration of fully anechoic rooms and correlation with OATS measurements
Fully anechoic rooms may gradually replace open area test sites as the preferred type of testing facility for the measurement of radiated emissions. The fully anechoic room offers several advantages over the open area test site. Immunity to high ambient signal levels, the capability of being located in metropolitan areas close to the customer base, more uniform field over a larger area a reduction in test time since there is no need to scan the receiving antenna in height, and the capability of being used for both emissions and susceptibility testing. Measurements of site attenuation in a fully anechoic room show excellent correlation with the mathematical model for normalized site attenuation in free space. The mathematical model and the measurement results are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信