构建极坐标系以确定吞咽过程中颈椎结构位置的初步研究

N. Kurita, Ayano Fujinaka, Kojiro Mekata, H. Takizawa, H. Kudo
{"title":"构建极坐标系以确定吞咽过程中颈椎结构位置的初步研究","authors":"N. Kurita, Ayano Fujinaka, Kojiro Mekata, H. Takizawa, H. Kudo","doi":"10.1109/ICIIBMS50712.2020.9336415","DOIUrl":null,"url":null,"abstract":"In this report, we have proposed a construction method of polar coordinate systems to define the positions of cervical structures in videofluorography (VF) during swallowing. The polar coordinate systems have s and t axes on radial and circumferential directions, respectively, and can be translated and rotated to track cervical spines in VFs. In addition, the t axes can be bent to represent the bending deformation of cervical spines. The parameters of the translation, rotation and bending deformation are obtained by a deformable template matching technique. The accuracy of the proposed coordinate systems was evaluated by use of actual VFs, and several experimental results were shown.","PeriodicalId":243033,"journal":{"name":"2020 5th International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary study on construction of polar coordinate systems to define the positions of cervical structures in videofluorography during swallowing\",\"authors\":\"N. Kurita, Ayano Fujinaka, Kojiro Mekata, H. Takizawa, H. Kudo\",\"doi\":\"10.1109/ICIIBMS50712.2020.9336415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this report, we have proposed a construction method of polar coordinate systems to define the positions of cervical structures in videofluorography (VF) during swallowing. The polar coordinate systems have s and t axes on radial and circumferential directions, respectively, and can be translated and rotated to track cervical spines in VFs. In addition, the t axes can be bent to represent the bending deformation of cervical spines. The parameters of the translation, rotation and bending deformation are obtained by a deformable template matching technique. The accuracy of the proposed coordinate systems was evaluated by use of actual VFs, and several experimental results were shown.\",\"PeriodicalId\":243033,\"journal\":{\"name\":\"2020 5th International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 5th International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIIBMS50712.2020.9336415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 5th International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIBMS50712.2020.9336415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本报告中,我们提出了一种极坐标系统的构建方法来定义吞咽过程中x线影像(VF)中颈椎结构的位置。极坐标系在径向和周向上分别具有s轴和t轴,并且可以平移和旋转以跟踪VFs中的颈椎。另外,t轴可以弯曲来表示颈椎的弯曲变形。通过可变形模板匹配技术获得了平移、旋转和弯曲变形参数。利用实际VFs对所提坐标系的精度进行了评价,并给出了几个实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preliminary study on construction of polar coordinate systems to define the positions of cervical structures in videofluorography during swallowing
In this report, we have proposed a construction method of polar coordinate systems to define the positions of cervical structures in videofluorography (VF) during swallowing. The polar coordinate systems have s and t axes on radial and circumferential directions, respectively, and can be translated and rotated to track cervical spines in VFs. In addition, the t axes can be bent to represent the bending deformation of cervical spines. The parameters of the translation, rotation and bending deformation are obtained by a deformable template matching technique. The accuracy of the proposed coordinate systems was evaluated by use of actual VFs, and several experimental results were shown.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信