{"title":"输电线路绝缘子故障对维护的影响","authors":"P. R. N. Silva, A. Carvalho, P. Vieira, C. T. Costa","doi":"10.1109/SEGE.2017.8052768","DOIUrl":null,"url":null,"abstract":"Outages in a transmission line occur due to failures that can develop abruptly, intermittently or incipiently. The incipient form of outage allows the monitoring and prediction of a possible fault. The incipient faults is often due to insulation problems, whether due to stresses, natural degradation or vandalism. Recent researches aim to diagnose failures in the isolation of transmission sections, and for this, mathematical models of transmission lines have been developed, whose insertion of the faulted insulator model allows to obtain leakage current to test the efficiency of this diagnosis. Considering the above, in this work, equivalent circuit models of failures in insulators are proposed, to characterize leakage current behavior for prediction purposes. The obtained models are used for validation of predictive maintenance methodologies, from the diagnosis of signals with faults, through the harmonic decomposition of the leakage current in transmission lines.","PeriodicalId":404327,"journal":{"name":"2017 IEEE International Conference on Smart Energy Grid Engineering (SEGE)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Characterization of failures in insulators to maintenance in transmission lines\",\"authors\":\"P. R. N. Silva, A. Carvalho, P. Vieira, C. T. Costa\",\"doi\":\"10.1109/SEGE.2017.8052768\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Outages in a transmission line occur due to failures that can develop abruptly, intermittently or incipiently. The incipient form of outage allows the monitoring and prediction of a possible fault. The incipient faults is often due to insulation problems, whether due to stresses, natural degradation or vandalism. Recent researches aim to diagnose failures in the isolation of transmission sections, and for this, mathematical models of transmission lines have been developed, whose insertion of the faulted insulator model allows to obtain leakage current to test the efficiency of this diagnosis. Considering the above, in this work, equivalent circuit models of failures in insulators are proposed, to characterize leakage current behavior for prediction purposes. The obtained models are used for validation of predictive maintenance methodologies, from the diagnosis of signals with faults, through the harmonic decomposition of the leakage current in transmission lines.\",\"PeriodicalId\":404327,\"journal\":{\"name\":\"2017 IEEE International Conference on Smart Energy Grid Engineering (SEGE)\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Conference on Smart Energy Grid Engineering (SEGE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SEGE.2017.8052768\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Smart Energy Grid Engineering (SEGE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEGE.2017.8052768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

输电线路的中断是由于突然、间歇或初期发生的故障造成的。中断的早期形式允许对可能的故障进行监视和预测。早期的故障通常是由于绝缘问题,无论是由于应力,自然退化还是人为破坏。最近的研究旨在诊断输电段隔离故障,为此建立了输电线路的数学模型,其中插入故障绝缘子模型可以获得泄漏电流,以测试该诊断的效率。考虑到上述情况,在这项工作中,提出了绝缘子失效的等效电路模型,以表征泄漏电流行为以进行预测。从故障信号的诊断到输电线路泄漏电流的谐波分解,所获得的模型用于验证预测性维护方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterization of failures in insulators to maintenance in transmission lines
Outages in a transmission line occur due to failures that can develop abruptly, intermittently or incipiently. The incipient form of outage allows the monitoring and prediction of a possible fault. The incipient faults is often due to insulation problems, whether due to stresses, natural degradation or vandalism. Recent researches aim to diagnose failures in the isolation of transmission sections, and for this, mathematical models of transmission lines have been developed, whose insertion of the faulted insulator model allows to obtain leakage current to test the efficiency of this diagnosis. Considering the above, in this work, equivalent circuit models of failures in insulators are proposed, to characterize leakage current behavior for prediction purposes. The obtained models are used for validation of predictive maintenance methodologies, from the diagnosis of signals with faults, through the harmonic decomposition of the leakage current in transmission lines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信