M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk
{"title":"双瓦计法参照系中有源滤波的积分策略","authors":"M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk","doi":"10.1109/EUROCON52738.2021.9535637","DOIUrl":null,"url":null,"abstract":"In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.","PeriodicalId":328338,"journal":{"name":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","volume":"416 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Integral Strategies of Active Filtration in the Reference Frame of the Two-Wattmeters Method\",\"authors\":\"M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk\",\"doi\":\"10.1109/EUROCON52738.2021.9535637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.\",\"PeriodicalId\":328338,\"journal\":{\"name\":\"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies\",\"volume\":\"416 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUROCON52738.2021.9535637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROCON52738.2021.9535637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Integral Strategies of Active Filtration in the Reference Frame of the Two-Wattmeters Method
In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.