双瓦计法参照系中有源滤波的积分策略

M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk
{"title":"双瓦计法参照系中有源滤波的积分策略","authors":"M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk","doi":"10.1109/EUROCON52738.2021.9535637","DOIUrl":null,"url":null,"abstract":"In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.","PeriodicalId":328338,"journal":{"name":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","volume":"416 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Integral Strategies of Active Filtration in the Reference Frame of the Two-Wattmeters Method\",\"authors\":\"M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk\",\"doi\":\"10.1109/EUROCON52738.2021.9535637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.\",\"PeriodicalId\":328338,\"journal\":{\"name\":\"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies\",\"volume\":\"416 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUROCON52738.2021.9535637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROCON52738.2021.9535637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了两种在双瓦计法参考系下的有源滤波积分策略,这两种策略实现简单、精度高、速度快。推导了三相三线制电力系统中负载不平衡和电压不平衡情况下有源滤波节能效果的计算公式。实验研究表明,提出的以线路非对称电压为参考矢量的有源滤波积分控制策略节能效果最好,但会产生不对称的市电电流。其中最有前途的是以直接序线电压为参考矢量的有源滤波积分控制策略,该策略可以提供几乎相同的节能效果,网络正弦电流对称,功耗纹波最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Integral Strategies of Active Filtration in the Reference Frame of the Two-Wattmeters Method
In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信