{"title":"一种确定配电系统中公用事业和用户谐波畸变贡献的新方法","authors":"M. Farhoodnea, A. Mohamed, H. Shareef","doi":"10.1109/PEOCO.2010.5559190","DOIUrl":null,"url":null,"abstract":"This paper presents a novel method for determining the contribution of harmonic distortion generated by utility and customer in a distribution system. The method considers modeling the customer side in terms of RLC components and the whole system is represented by a Norton equivalent circuit. Voltage and current at the point of common coupling are then measured to calculate the customer and utility harmonic current and voltage contributions. Simulations were carried out the 10 bus test system to verify the accuracy of the method.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Novel method for determining the contribution of utility and customer harmonic distortion in distribution systems\",\"authors\":\"M. Farhoodnea, A. Mohamed, H. Shareef\",\"doi\":\"10.1109/PEOCO.2010.5559190\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel method for determining the contribution of harmonic distortion generated by utility and customer in a distribution system. The method considers modeling the customer side in terms of RLC components and the whole system is represented by a Norton equivalent circuit. Voltage and current at the point of common coupling are then measured to calculate the customer and utility harmonic current and voltage contributions. Simulations were carried out the 10 bus test system to verify the accuracy of the method.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559190\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel method for determining the contribution of utility and customer harmonic distortion in distribution systems
This paper presents a novel method for determining the contribution of harmonic distortion generated by utility and customer in a distribution system. The method considers modeling the customer side in terms of RLC components and the whole system is represented by a Norton equivalent circuit. Voltage and current at the point of common coupling are then measured to calculate the customer and utility harmonic current and voltage contributions. Simulations were carried out the 10 bus test system to verify the accuracy of the method.