电压暂降在线监测系统的故障定位与设计

Chong Liu, Lijun Tian, Yanwen Hou, Yunxing Gao
{"title":"电压暂降在线监测系统的故障定位与设计","authors":"Chong Liu, Lijun Tian, Yanwen Hou, Yunxing Gao","doi":"10.1145/3277453.3277457","DOIUrl":null,"url":null,"abstract":"In modern power systems, the methods of voltage sag monitors optimal placement and fault assessment are based on fixed threshold detection system, which affect the method's accuracy. To change this limitation, an active information extraction on-line monitoring system for voltage sag is developed. The monitor is based on STM32 microcontroller chip, using GPRS to communicate with the host computer. A new monitor reach area method considering fault location is proposed. LabVIEW is used to build servers. The host computer uses a new fault location method to analyze the uploaded information. The simulation results show that the new design of the system can accurately locate the fault location and evaluate the voltage sag state of the network.","PeriodicalId":186835,"journal":{"name":"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology","volume":"127 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Fault Location and Design of On-Line Monitoring System for Voltage Sag\",\"authors\":\"Chong Liu, Lijun Tian, Yanwen Hou, Yunxing Gao\",\"doi\":\"10.1145/3277453.3277457\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In modern power systems, the methods of voltage sag monitors optimal placement and fault assessment are based on fixed threshold detection system, which affect the method's accuracy. To change this limitation, an active information extraction on-line monitoring system for voltage sag is developed. The monitor is based on STM32 microcontroller chip, using GPRS to communicate with the host computer. A new monitor reach area method considering fault location is proposed. LabVIEW is used to build servers. The host computer uses a new fault location method to analyze the uploaded information. The simulation results show that the new design of the system can accurately locate the fault location and evaluate the voltage sag state of the network.\",\"PeriodicalId\":186835,\"journal\":{\"name\":\"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology\",\"volume\":\"127 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3277453.3277457\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3277453.3277457","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在现代电力系统中,电压暂降监测的优化配置和故障评估方法都是基于固定阈值检测系统,这影响了方法的准确性。为了改变这一局限,研制了一种电压暂降主动信息提取在线监测系统。该监视器以STM32单片机为核心,采用GPRS与上位机通信。提出了一种考虑故障定位的监测范围新方法。LabVIEW用于构建服务器。主机采用一种新的故障定位方法对上传的信息进行分析。仿真结果表明,新设计的系统能够准确地定位故障位置并评估电网的电压暂降状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault Location and Design of On-Line Monitoring System for Voltage Sag
In modern power systems, the methods of voltage sag monitors optimal placement and fault assessment are based on fixed threshold detection system, which affect the method's accuracy. To change this limitation, an active information extraction on-line monitoring system for voltage sag is developed. The monitor is based on STM32 microcontroller chip, using GPRS to communicate with the host computer. A new monitor reach area method considering fault location is proposed. LabVIEW is used to build servers. The host computer uses a new fault location method to analyze the uploaded information. The simulation results show that the new design of the system can accurately locate the fault location and evaluate the voltage sag state of the network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信