{"title":"基于相电流优化剖面的开关磁阻电机转矩纹波抑制","authors":"D. S. Schramm, B. Williams, T. Green","doi":"10.1109/PESC.1992.254793","DOIUrl":null,"url":null,"abstract":"Optimal precalculation of the position-phase current profile for current feeding a four-phase, 4 kW switched reluctance motor results in a single-input, linear, decoupled output torque controller that provides low torque ripple. A bicubic spline interpolation was used to model the nonlinear experimental data. The algorithm is based on minimizing both the average and peak current and hence improves the dynamic performance of the novel six-switch, current-fed, 4 kW, 40 kHz IGBT inverter. Test results are presented.<<ETX>>","PeriodicalId":402706,"journal":{"name":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"181","resultStr":"{\"title\":\"Torque ripple reduction of switched reluctance motors by phase current optimal profiling\",\"authors\":\"D. S. Schramm, B. Williams, T. Green\",\"doi\":\"10.1109/PESC.1992.254793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optimal precalculation of the position-phase current profile for current feeding a four-phase, 4 kW switched reluctance motor results in a single-input, linear, decoupled output torque controller that provides low torque ripple. A bicubic spline interpolation was used to model the nonlinear experimental data. The algorithm is based on minimizing both the average and peak current and hence improves the dynamic performance of the novel six-switch, current-fed, 4 kW, 40 kHz IGBT inverter. Test results are presented.<<ETX>>\",\"PeriodicalId\":402706,\"journal\":{\"name\":\"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"181\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1992.254793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1992.254793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Torque ripple reduction of switched reluctance motors by phase current optimal profiling
Optimal precalculation of the position-phase current profile for current feeding a four-phase, 4 kW switched reluctance motor results in a single-input, linear, decoupled output torque controller that provides low torque ripple. A bicubic spline interpolation was used to model the nonlinear experimental data. The algorithm is based on minimizing both the average and peak current and hence improves the dynamic performance of the novel six-switch, current-fed, 4 kW, 40 kHz IGBT inverter. Test results are presented.<>