{"title":"基于dfig的风电场瞬态行为增强的能量电容系统","authors":"J. Morel, T. Hiyama","doi":"10.1109/TD-ASIA.2009.5356996","DOIUrl":null,"url":null,"abstract":"This paper presents the advantages of the utilization of a small-sized Energy Capacitor System (ECS) in a power system including a Doubly Fed Induction Generator (DFIG) based wind farm. In order to show its impact in the transient behavior, the ECS was located in the terminal of the wind farm. A four-machine infinite bus system was considered. One of the units was considered as an aggregated model of DFIG-based wind turbines (WT). A three-phase to ground fault was applied to a nearby line and the WTs were considered protected by standard crowbar with converter fast reconnection system. The small-sized ECS shows a positive effect not only in the WT but also in the synchronous units, such as reduction in WT mechanical stress and power oscillations. Despite the limited energy storage capacity a reasonable power output smoothing was obtained. Results show an important improvement in the system transient behavior.","PeriodicalId":131589,"journal":{"name":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Energy capacitor system for DFIG-based wind farm transient behavior enhancement\",\"authors\":\"J. Morel, T. Hiyama\",\"doi\":\"10.1109/TD-ASIA.2009.5356996\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the advantages of the utilization of a small-sized Energy Capacitor System (ECS) in a power system including a Doubly Fed Induction Generator (DFIG) based wind farm. In order to show its impact in the transient behavior, the ECS was located in the terminal of the wind farm. A four-machine infinite bus system was considered. One of the units was considered as an aggregated model of DFIG-based wind turbines (WT). A three-phase to ground fault was applied to a nearby line and the WTs were considered protected by standard crowbar with converter fast reconnection system. The small-sized ECS shows a positive effect not only in the WT but also in the synchronous units, such as reduction in WT mechanical stress and power oscillations. Despite the limited energy storage capacity a reasonable power output smoothing was obtained. Results show an important improvement in the system transient behavior.\",\"PeriodicalId\":131589,\"journal\":{\"name\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"volume\":\"80 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TD-ASIA.2009.5356996\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Transmission & Distribution Conference & Exposition: Asia and Pacific","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TD-ASIA.2009.5356996","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Energy capacitor system for DFIG-based wind farm transient behavior enhancement
This paper presents the advantages of the utilization of a small-sized Energy Capacitor System (ECS) in a power system including a Doubly Fed Induction Generator (DFIG) based wind farm. In order to show its impact in the transient behavior, the ECS was located in the terminal of the wind farm. A four-machine infinite bus system was considered. One of the units was considered as an aggregated model of DFIG-based wind turbines (WT). A three-phase to ground fault was applied to a nearby line and the WTs were considered protected by standard crowbar with converter fast reconnection system. The small-sized ECS shows a positive effect not only in the WT but also in the synchronous units, such as reduction in WT mechanical stress and power oscillations. Despite the limited energy storage capacity a reasonable power output smoothing was obtained. Results show an important improvement in the system transient behavior.