{"title":"基于共享塔比例模型的暗室电磁场测试","authors":"Zeyang Tang, Fei Yu, Wei Rao, Su Lv, Yibo Cui, Wenshuo Wang","doi":"10.1109/ICPECA53709.2022.9719114","DOIUrl":null,"url":null,"abstract":"In order to test the effectiveness of the shared tower scale model, the shared tower scale model has been built in the anechoic chamber, and the electromagnetic scattering field test of a single base station antenna and three base station antennas has been carried out. The electric field strength test value and theoretical calculated value at different distances under three frequencies have been compared. The results indicate that the change trend of the measured value and the theoretical calculation value is roughly the same, and the global maximum relative deviation is 8.89%. Combined with error analysis, the accuracy of the shared tower reduction model is basically verified.","PeriodicalId":244448,"journal":{"name":"2022 IEEE 2nd International Conference on Power, Electronics and Computer Applications (ICPECA)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electromagnetic Field Tests in the Anechoic Chamber Based on the Shared Tower Scale Model\",\"authors\":\"Zeyang Tang, Fei Yu, Wei Rao, Su Lv, Yibo Cui, Wenshuo Wang\",\"doi\":\"10.1109/ICPECA53709.2022.9719114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to test the effectiveness of the shared tower scale model, the shared tower scale model has been built in the anechoic chamber, and the electromagnetic scattering field test of a single base station antenna and three base station antennas has been carried out. The electric field strength test value and theoretical calculated value at different distances under three frequencies have been compared. The results indicate that the change trend of the measured value and the theoretical calculation value is roughly the same, and the global maximum relative deviation is 8.89%. Combined with error analysis, the accuracy of the shared tower reduction model is basically verified.\",\"PeriodicalId\":244448,\"journal\":{\"name\":\"2022 IEEE 2nd International Conference on Power, Electronics and Computer Applications (ICPECA)\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 2nd International Conference on Power, Electronics and Computer Applications (ICPECA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPECA53709.2022.9719114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 2nd International Conference on Power, Electronics and Computer Applications (ICPECA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPECA53709.2022.9719114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了验证共享塔比模型的有效性,在消声室中建立了共享塔比模型,并进行了单基站天线和三基站天线的电磁散射场测试。对三种频率下不同距离的电场强度试验值与理论计算值进行了比较。结果表明,实测值与理论计算值的变化趋势基本一致,全球最大相对偏差为8.89%。结合误差分析,基本验证了共享减塔模型的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electromagnetic Field Tests in the Anechoic Chamber Based on the Shared Tower Scale Model
In order to test the effectiveness of the shared tower scale model, the shared tower scale model has been built in the anechoic chamber, and the electromagnetic scattering field test of a single base station antenna and three base station antennas has been carried out. The electric field strength test value and theoretical calculated value at different distances under three frequencies have been compared. The results indicate that the change trend of the measured value and the theoretical calculation value is roughly the same, and the global maximum relative deviation is 8.89%. Combined with error analysis, the accuracy of the shared tower reduction model is basically verified.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信