利用市售单克隆抗体对头发样本ABO血型进行吸收-洗脱试验的最佳洗脱温度和时间

T. Ohmori, Hajime Sato
{"title":"利用市售单克隆抗体对头发样本ABO血型进行吸收-洗脱试验的最佳洗脱温度和时间","authors":"T. Ohmori, Hajime Sato","doi":"10.3408/JASTI.6.49","DOIUrl":null,"url":null,"abstract":"The optimum elution temperature and optimum elution time of absorption-elution test for ABO blood-typing from hair samples using commercially available monoclonal antibody were examined. Elution temperature was examined in the range of 51-57°C and elution time was examined in the range of 2-15 min. The eluting antibodies were semi-quantitatively analyzed by ELISA using synthetic blood group antigens. The optimum elution temperature and optimum elution time were determined for each monoclonal antibody. The procedure of absorption-elution method for hair samples was improved and the improved procedure was evaluated by a blind test. The improved procedure of the absorption-elution test gave a satisfactory result.","PeriodicalId":134327,"journal":{"name":"Japanese Journal of Science and Technology for Identification","volume":"260 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The Optimum Elution Temperature and Time in Absorption-Elution Test Using Commercially Available Monoclonal Antibodies for ABO Blood-Typing from Hair Samples\",\"authors\":\"T. Ohmori, Hajime Sato\",\"doi\":\"10.3408/JASTI.6.49\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The optimum elution temperature and optimum elution time of absorption-elution test for ABO blood-typing from hair samples using commercially available monoclonal antibody were examined. Elution temperature was examined in the range of 51-57°C and elution time was examined in the range of 2-15 min. The eluting antibodies were semi-quantitatively analyzed by ELISA using synthetic blood group antigens. The optimum elution temperature and optimum elution time were determined for each monoclonal antibody. The procedure of absorption-elution method for hair samples was improved and the improved procedure was evaluated by a blind test. The improved procedure of the absorption-elution test gave a satisfactory result.\",\"PeriodicalId\":134327,\"journal\":{\"name\":\"Japanese Journal of Science and Technology for Identification\",\"volume\":\"260 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Science and Technology for Identification\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3408/JASTI.6.49\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Science and Technology for Identification","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3408/JASTI.6.49","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

探讨了市售单克隆抗体对头发样品ABO血型的吸收-洗脱试验的最佳洗脱温度和最佳洗脱时间。洗脱温度为51 ~ 57℃,洗脱时间为2 ~ 15 min。ELISA法采用合成血型抗原对洗脱抗体进行半定量分析。确定各单克隆抗体的最佳洗脱温度和最佳洗脱时间。对毛发样品的吸收-洗脱方法进行了改进,并通过盲法试验对改进后的方法进行了评价。改进的吸收-洗脱试验方法取得了满意的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Optimum Elution Temperature and Time in Absorption-Elution Test Using Commercially Available Monoclonal Antibodies for ABO Blood-Typing from Hair Samples
The optimum elution temperature and optimum elution time of absorption-elution test for ABO blood-typing from hair samples using commercially available monoclonal antibody were examined. Elution temperature was examined in the range of 51-57°C and elution time was examined in the range of 2-15 min. The eluting antibodies were semi-quantitatively analyzed by ELISA using synthetic blood group antigens. The optimum elution temperature and optimum elution time were determined for each monoclonal antibody. The procedure of absorption-elution method for hair samples was improved and the improved procedure was evaluated by a blind test. The improved procedure of the absorption-elution test gave a satisfactory result.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信