Oskari Leppäaho, F. Lafon, Bruno Ferreri, P. Fernandez-Lopez, Marine Stojanovic, R. Perdriau, M. Ramdani
{"title":"将屏蔽电缆的老化实验纳入大电流注入模拟","authors":"Oskari Leppäaho, F. Lafon, Bruno Ferreri, P. Fernandez-Lopez, Marine Stojanovic, R. Perdriau, M. Ramdani","doi":"10.1109/EMCEurope51680.2022.9901089","DOIUrl":null,"url":null,"abstract":"Transfer impedance of shielded cables is a main characteristic to describe cable shielding performance at least up to 1 GHz. Traditionally, a cable shield consists of a braid, a foil, or a combination of them. Braids have attracted a significant amount of research interest, while foils have not. Published studies have concentrated on cable shielding performance when cables are new. In this paper, a highly accelerated aging method for shielded cables is presented and applied to a cable made up of a combination of a braid and foil shield. Finally, the effect of aging on system performance during bulk current injection (BCI) tests is assessed by circuit simulation.","PeriodicalId":268262,"journal":{"name":"2022 International Symposium on Electromagnetic Compatibility – EMC Europe","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Including Experimental Aging of Shielded Cables into Bulk Current Injection Simulations\",\"authors\":\"Oskari Leppäaho, F. Lafon, Bruno Ferreri, P. Fernandez-Lopez, Marine Stojanovic, R. Perdriau, M. Ramdani\",\"doi\":\"10.1109/EMCEurope51680.2022.9901089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transfer impedance of shielded cables is a main characteristic to describe cable shielding performance at least up to 1 GHz. Traditionally, a cable shield consists of a braid, a foil, or a combination of them. Braids have attracted a significant amount of research interest, while foils have not. Published studies have concentrated on cable shielding performance when cables are new. In this paper, a highly accelerated aging method for shielded cables is presented and applied to a cable made up of a combination of a braid and foil shield. Finally, the effect of aging on system performance during bulk current injection (BCI) tests is assessed by circuit simulation.\",\"PeriodicalId\":268262,\"journal\":{\"name\":\"2022 International Symposium on Electromagnetic Compatibility – EMC Europe\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Symposium on Electromagnetic Compatibility – EMC Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEurope51680.2022.9901089\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Symposium on Electromagnetic Compatibility – EMC Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEurope51680.2022.9901089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Including Experimental Aging of Shielded Cables into Bulk Current Injection Simulations
Transfer impedance of shielded cables is a main characteristic to describe cable shielding performance at least up to 1 GHz. Traditionally, a cable shield consists of a braid, a foil, or a combination of them. Braids have attracted a significant amount of research interest, while foils have not. Published studies have concentrated on cable shielding performance when cables are new. In this paper, a highly accelerated aging method for shielded cables is presented and applied to a cable made up of a combination of a braid and foil shield. Finally, the effect of aging on system performance during bulk current injection (BCI) tests is assessed by circuit simulation.