新的信号处理技术提高阻抗心动图的可靠性

L. Shyu, S. P. Reddy, J. Nagel, N. Schneiderman
{"title":"新的信号处理技术提高阻抗心动图的可靠性","authors":"L. Shyu, S. P. Reddy, J. Nagel, N. Schneiderman","doi":"10.1109/IEMBS.1988.94395","DOIUrl":null,"url":null,"abstract":"Different techniques have been developed for parameter extraction and segmentation of the impedance cardiogram for improved reliability and precision of beat-to-beat determination of systolic time intervals, stroke volume, and related cardiac indices. The solutions presented improve on previous techniques by: (1) substantially reducing jitter in the localization of events within the cardiac cycle; (2) providing exact determination of signal amplitudes even in the presence of artifacts and interference signals; and (3) eliminating the influence of respiratory signal modulation on parameter extraction.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"New signal processing techniques for improved reliability of impedance cardiography\",\"authors\":\"L. Shyu, S. P. Reddy, J. Nagel, N. Schneiderman\",\"doi\":\"10.1109/IEMBS.1988.94395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different techniques have been developed for parameter extraction and segmentation of the impedance cardiogram for improved reliability and precision of beat-to-beat determination of systolic time intervals, stroke volume, and related cardiac indices. The solutions presented improve on previous techniques by: (1) substantially reducing jitter in the localization of events within the cardiac cycle; (2) providing exact determination of signal amplitudes even in the presence of artifacts and interference signals; and (3) eliminating the influence of respiratory signal modulation on parameter extraction.<<ETX>>\",\"PeriodicalId\":227170,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1988.94395\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了提高心跳间隔、搏量和相关心脏指标的可靠性和准确性,已经开发了不同的技术用于阻抗心电图的参数提取和分割。提出的解决方案改进了以前的技术:(1)大大减少了心周期内事件定位的抖动;(2)即使存在伪影和干扰信号,也能精确测定信号幅度;③消除呼吸信号调制对参数提取的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New signal processing techniques for improved reliability of impedance cardiography
Different techniques have been developed for parameter extraction and segmentation of the impedance cardiogram for improved reliability and precision of beat-to-beat determination of systolic time intervals, stroke volume, and related cardiac indices. The solutions presented improve on previous techniques by: (1) substantially reducing jitter in the localization of events within the cardiac cycle; (2) providing exact determination of signal amplitudes even in the presence of artifacts and interference signals; and (3) eliminating the influence of respiratory signal modulation on parameter extraction.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信