光纤生理弯曲传感器传感范围评估

M. Zawawi, S. O’Keeffe, E. Lewis
{"title":"光纤生理弯曲传感器传感范围评估","authors":"M. Zawawi, S. O’Keeffe, E. Lewis","doi":"10.1109/ICP.2013.6687083","DOIUrl":null,"url":null,"abstract":"This paper presents the investigation of sensing range limit for intensity modulated optical fibre bending sensor using single input and dual input fibres. Plastic optical fibre is used to measure the bending angle by measuring the changes of light intensity using tilt angle loss measurement approach. To define the bending range of the sensor configurations under investigation, the fibre was bended at several bending angle for a 30 second period purposely to reduce the effect of light source fluctuation and drift in measurement. It was found that, with the use of dual input source fibres, the bending angle range can be extended at almost twice angle range than the single input fibre but with a lower output resolution.","PeriodicalId":308672,"journal":{"name":"2013 IEEE 4th International Conference on Photonics (ICP)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensing range assessment of optical fibre physiological bending sensor\",\"authors\":\"M. Zawawi, S. O’Keeffe, E. Lewis\",\"doi\":\"10.1109/ICP.2013.6687083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the investigation of sensing range limit for intensity modulated optical fibre bending sensor using single input and dual input fibres. Plastic optical fibre is used to measure the bending angle by measuring the changes of light intensity using tilt angle loss measurement approach. To define the bending range of the sensor configurations under investigation, the fibre was bended at several bending angle for a 30 second period purposely to reduce the effect of light source fluctuation and drift in measurement. It was found that, with the use of dual input source fibres, the bending angle range can be extended at almost twice angle range than the single input fibre but with a lower output resolution.\",\"PeriodicalId\":308672,\"journal\":{\"name\":\"2013 IEEE 4th International Conference on Photonics (ICP)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 4th International Conference on Photonics (ICP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICP.2013.6687083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 4th International Conference on Photonics (ICP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICP.2013.6687083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了单输入和双输入强度调制光纤弯曲传感器的传感范围限制问题。采用倾斜角损耗测量方法,通过测量光强的变化来测量塑料光纤的弯曲角。为了确定所研究的传感器配置的弯曲范围,将光纤以几个弯曲角度弯曲30秒,以减少测量中光源波动和漂移的影响。研究发现,使用双输入源光纤,弯曲角度范围可以扩展到几乎两倍于单输入源光纤的角度范围,但输出分辨率较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensing range assessment of optical fibre physiological bending sensor
This paper presents the investigation of sensing range limit for intensity modulated optical fibre bending sensor using single input and dual input fibres. Plastic optical fibre is used to measure the bending angle by measuring the changes of light intensity using tilt angle loss measurement approach. To define the bending range of the sensor configurations under investigation, the fibre was bended at several bending angle for a 30 second period purposely to reduce the effect of light source fluctuation and drift in measurement. It was found that, with the use of dual input source fibres, the bending angle range can be extended at almost twice angle range than the single input fibre but with a lower output resolution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信