C. Martelli, J. D. da Silva, H. Kalinowski, J. Canning, N. Groothoff
{"title":"用高温稳定光纤布拉格光栅测量混凝土悬臂梁的内部温度","authors":"C. Martelli, J. D. da Silva, H. Kalinowski, J. Canning, N. Groothoff","doi":"10.1109/ACOFT.2006.4519239","DOIUrl":null,"url":null,"abstract":"A high temperature sensing system based on optical fibre Bragg gratings is presented. A concrete cantilever beam was heated up to 150degC and its internal temperature and degradation monitored.","PeriodicalId":244615,"journal":{"name":"ACOFT/AOS 2006 - Australian Conference on Optical Fibre Technology/Australian Optical Society","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Internal temperature measurements of a concrete cantilever beam using high temperature stable fibre Bragg gratings\",\"authors\":\"C. Martelli, J. D. da Silva, H. Kalinowski, J. Canning, N. Groothoff\",\"doi\":\"10.1109/ACOFT.2006.4519239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A high temperature sensing system based on optical fibre Bragg gratings is presented. A concrete cantilever beam was heated up to 150degC and its internal temperature and degradation monitored.\",\"PeriodicalId\":244615,\"journal\":{\"name\":\"ACOFT/AOS 2006 - Australian Conference on Optical Fibre Technology/Australian Optical Society\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACOFT/AOS 2006 - Australian Conference on Optical Fibre Technology/Australian Optical Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACOFT.2006.4519239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACOFT/AOS 2006 - Australian Conference on Optical Fibre Technology/Australian Optical Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACOFT.2006.4519239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Internal temperature measurements of a concrete cantilever beam using high temperature stable fibre Bragg gratings
A high temperature sensing system based on optical fibre Bragg gratings is presented. A concrete cantilever beam was heated up to 150degC and its internal temperature and degradation monitored.