基于电流和电压观测的并网光伏系统短开路故障检测

Sugirianta Ibk, IGNA Dwijaya_S, M Purbhawa, GK Sri Budarsa, Ketut Ta
{"title":"基于电流和电压观测的并网光伏系统短开路故障检测","authors":"Sugirianta Ibk, IGNA Dwijaya_S, M Purbhawa, GK Sri Budarsa, Ketut Ta","doi":"10.32996/jcsts.2022.4.2.13","DOIUrl":null,"url":null,"abstract":"Photovoltaic (PV) systems as clean and green electrical energy generators have increased sharply in the last 10 years. The installation of a PV system in an open area is one of the causes of frequent faults/damage to the PV system. Fault in the PV system causes a decrease in efficiency, weak reliability, and disruption of the continuity of the electrical power distribution, which in turn causes the low performance of the system. This research does on the on-grid PV system 1MWp Bangli which consists of 278 PV arrays and 5004 monocrystalline solar modules 200Wp, which started operation in 2013. This research aims to find open circuit and short circuit faults that occur in the PV system Bangli. The method used in this research is the current and voltage observation method. Current and output voltage measurements from the PV array are carried out as well as measurements of working module temperature and solar irradiance. To calculate the output PV array's current (RI) and voltage (RV) indicators; Calculation of the current (RIM) and voltage (RVM) indicators under fault-free conditions, and the short circuit (TIO) and open voltage (TVS) threshold are calculated. As a result, this study succeeded in determining short and open circuit faults that occur in PV systems on grid 1MWp Bangli.","PeriodicalId":417206,"journal":{"name":"Journal of Computer Science and Technology Studies","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short and Open Circuit Fault Detection in On-Grid Photovoltaic Systems 1MWP Bangli Based on Current and Voltage Observation\",\"authors\":\"Sugirianta Ibk, IGNA Dwijaya_S, M Purbhawa, GK Sri Budarsa, Ketut Ta\",\"doi\":\"10.32996/jcsts.2022.4.2.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Photovoltaic (PV) systems as clean and green electrical energy generators have increased sharply in the last 10 years. The installation of a PV system in an open area is one of the causes of frequent faults/damage to the PV system. Fault in the PV system causes a decrease in efficiency, weak reliability, and disruption of the continuity of the electrical power distribution, which in turn causes the low performance of the system. This research does on the on-grid PV system 1MWp Bangli which consists of 278 PV arrays and 5004 monocrystalline solar modules 200Wp, which started operation in 2013. This research aims to find open circuit and short circuit faults that occur in the PV system Bangli. The method used in this research is the current and voltage observation method. Current and output voltage measurements from the PV array are carried out as well as measurements of working module temperature and solar irradiance. To calculate the output PV array's current (RI) and voltage (RV) indicators; Calculation of the current (RIM) and voltage (RVM) indicators under fault-free conditions, and the short circuit (TIO) and open voltage (TVS) threshold are calculated. As a result, this study succeeded in determining short and open circuit faults that occur in PV systems on grid 1MWp Bangli.\",\"PeriodicalId\":417206,\"journal\":{\"name\":\"Journal of Computer Science and Technology Studies\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Computer Science and Technology Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32996/jcsts.2022.4.2.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Science and Technology Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32996/jcsts.2022.4.2.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

光伏(PV)系统作为一种清洁、绿色的发电设备,在过去的十年中得到了迅速的发展。光伏系统安装在开阔区域是光伏系统频繁故障/损坏的原因之一。光伏系统发生故障,会导致系统效率下降、可靠性不高、配电的连续性中断,从而导致系统性能下降。本研究对2013年开始运行的并网光伏系统1MWp Bangli进行了研究,该系统由278个光伏阵列和5004个200Wp单晶太阳能组件组成。本研究旨在找出邦利光伏系统中发生的开路和短路故障。本研究采用的方法是电流和电压观察法。从光伏阵列进行电流和输出电压测量,以及工作模块温度和太阳辐照度的测量。计算输出光伏阵列的电流(RI)和电压(RV)指标;计算无故障情况下的电流(RIM)和电压(RVM)指标,并计算短路(TIO)和开路电压(TVS)阈值。因此,本研究成功地确定了1MWp Bangli电网光伏系统中发生的短路和开路故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short and Open Circuit Fault Detection in On-Grid Photovoltaic Systems 1MWP Bangli Based on Current and Voltage Observation
Photovoltaic (PV) systems as clean and green electrical energy generators have increased sharply in the last 10 years. The installation of a PV system in an open area is one of the causes of frequent faults/damage to the PV system. Fault in the PV system causes a decrease in efficiency, weak reliability, and disruption of the continuity of the electrical power distribution, which in turn causes the low performance of the system. This research does on the on-grid PV system 1MWp Bangli which consists of 278 PV arrays and 5004 monocrystalline solar modules 200Wp, which started operation in 2013. This research aims to find open circuit and short circuit faults that occur in the PV system Bangli. The method used in this research is the current and voltage observation method. Current and output voltage measurements from the PV array are carried out as well as measurements of working module temperature and solar irradiance. To calculate the output PV array's current (RI) and voltage (RV) indicators; Calculation of the current (RIM) and voltage (RVM) indicators under fault-free conditions, and the short circuit (TIO) and open voltage (TVS) threshold are calculated. As a result, this study succeeded in determining short and open circuit faults that occur in PV systems on grid 1MWp Bangli.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信