{"title":"三相永磁同步电动机绕组故障综合诊断系统","authors":"Lukáš Otava, Ludek Buchta","doi":"10.1109/ICUMT51630.2020.9222438","DOIUrl":null,"url":null,"abstract":"This paper deals with the detection of the winding faults of the three-phase PMSM. The algorithm based on the three-phase model of the winding and the extended Kalman filter is used for inter-turn short detection. Additionally, the functionality of the sensors used for the detection algorithms is verified. The decision system is in charge of the diagnosis of the fault (winding/sensors). All the presented algorithms were implemented in Simulink and tested on data measured on a real inverter with the motor connected to the dynamometer. Algorithms were also tested on a microcontroller.","PeriodicalId":170847,"journal":{"name":"2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Integrated diagnostic system for winding fault detection of the three-phase PMSM\",\"authors\":\"Lukáš Otava, Ludek Buchta\",\"doi\":\"10.1109/ICUMT51630.2020.9222438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the detection of the winding faults of the three-phase PMSM. The algorithm based on the three-phase model of the winding and the extended Kalman filter is used for inter-turn short detection. Additionally, the functionality of the sensors used for the detection algorithms is verified. The decision system is in charge of the diagnosis of the fault (winding/sensors). All the presented algorithms were implemented in Simulink and tested on data measured on a real inverter with the motor connected to the dynamometer. Algorithms were also tested on a microcontroller.\",\"PeriodicalId\":170847,\"journal\":{\"name\":\"2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICUMT51630.2020.9222438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 12th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICUMT51630.2020.9222438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Integrated diagnostic system for winding fault detection of the three-phase PMSM
This paper deals with the detection of the winding faults of the three-phase PMSM. The algorithm based on the three-phase model of the winding and the extended Kalman filter is used for inter-turn short detection. Additionally, the functionality of the sensors used for the detection algorithms is verified. The decision system is in charge of the diagnosis of the fault (winding/sensors). All the presented algorithms were implemented in Simulink and tested on data measured on a real inverter with the motor connected to the dynamometer. Algorithms were also tested on a microcontroller.