Tianran Zheng, F. Wang, Den'en Wang, X. Sun, Hong-jie Liu, Liangming Chen, D. Hu
{"title":"大功率激光系统中会聚散光焦斑吸收器的设计","authors":"Tianran Zheng, F. Wang, Den'en Wang, X. Sun, Hong-jie Liu, Liangming Chen, D. Hu","doi":"10.1117/12.2539705","DOIUrl":null,"url":null,"abstract":"In high power solid-state laser facilities, stray lights may do great damage to optical glass and metal structure and affect the transmission of the main laser and the environment cleanliness inside the facility. On the other hand, the stray may also form noise signal of the main laser pulse and affect the output quality. There are mature solutions for the controlling and absorption of parallel and divergent stray light[2]. However there are no reliable solution for the absorption of the converging stray light near its focal spot. An absorber design are proposed using multiple materials and small angle light cone. And this design can realize effective absorption of the stray light focal spot with the peak fluence up to 40J/cm2.","PeriodicalId":197837,"journal":{"name":"SPIE/SIOM Pacific Rim Laser Damage","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Designing of converging stray light focal spot absorber in high power laser system\",\"authors\":\"Tianran Zheng, F. Wang, Den'en Wang, X. Sun, Hong-jie Liu, Liangming Chen, D. Hu\",\"doi\":\"10.1117/12.2539705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In high power solid-state laser facilities, stray lights may do great damage to optical glass and metal structure and affect the transmission of the main laser and the environment cleanliness inside the facility. On the other hand, the stray may also form noise signal of the main laser pulse and affect the output quality. There are mature solutions for the controlling and absorption of parallel and divergent stray light[2]. However there are no reliable solution for the absorption of the converging stray light near its focal spot. An absorber design are proposed using multiple materials and small angle light cone. And this design can realize effective absorption of the stray light focal spot with the peak fluence up to 40J/cm2.\",\"PeriodicalId\":197837,\"journal\":{\"name\":\"SPIE/SIOM Pacific Rim Laser Damage\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SPIE/SIOM Pacific Rim Laser Damage\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2539705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPIE/SIOM Pacific Rim Laser Damage","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2539705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Designing of converging stray light focal spot absorber in high power laser system
In high power solid-state laser facilities, stray lights may do great damage to optical glass and metal structure and affect the transmission of the main laser and the environment cleanliness inside the facility. On the other hand, the stray may also form noise signal of the main laser pulse and affect the output quality. There are mature solutions for the controlling and absorption of parallel and divergent stray light[2]. However there are no reliable solution for the absorption of the converging stray light near its focal spot. An absorber design are proposed using multiple materials and small angle light cone. And this design can realize effective absorption of the stray light focal spot with the peak fluence up to 40J/cm2.