{"title":"多焦点视网膜电图评估孤立性中央凹发育不全:临床表现","authors":"K. Mok","doi":"10.46889/joar.2022.3301","DOIUrl":null,"url":null,"abstract":"Spherical Refractive error (Rx) has been reported to be reliably estimated with Ocular Biometrics (OB) using intra-ocular lens calculation method such as SRK/T formula [1]. Further supplementary data was presented regarding the evaluation of the extent of Rx alterations with Axial Length (AL) elongation using this calculation method.\n\nRx were calculated using intraocular lens power (IOL) (22.5D A-Constant 118) and various AL (23.0 to 26.0 mm) and corneal curvature (K) readings (41.00 to 44.00 D) using SRK/T formula. IOL was estimated with Rx (Plano), AL (23.2 mm) and K reading (42.00 D).","PeriodicalId":348405,"journal":{"name":"Journal of Ophthalmology and Advance Research","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Isolated Foveal Hypoplasia Assessed by Multi-Focal Electroretinogram: A Clinical Presentation\",\"authors\":\"K. Mok\",\"doi\":\"10.46889/joar.2022.3301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spherical Refractive error (Rx) has been reported to be reliably estimated with Ocular Biometrics (OB) using intra-ocular lens calculation method such as SRK/T formula [1]. Further supplementary data was presented regarding the evaluation of the extent of Rx alterations with Axial Length (AL) elongation using this calculation method.\\n\\nRx were calculated using intraocular lens power (IOL) (22.5D A-Constant 118) and various AL (23.0 to 26.0 mm) and corneal curvature (K) readings (41.00 to 44.00 D) using SRK/T formula. IOL was estimated with Rx (Plano), AL (23.2 mm) and K reading (42.00 D).\",\"PeriodicalId\":348405,\"journal\":{\"name\":\"Journal of Ophthalmology and Advance Research\",\"volume\":\"112 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ophthalmology and Advance Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46889/joar.2022.3301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology and Advance Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46889/joar.2022.3301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Isolated Foveal Hypoplasia Assessed by Multi-Focal Electroretinogram: A Clinical Presentation
Spherical Refractive error (Rx) has been reported to be reliably estimated with Ocular Biometrics (OB) using intra-ocular lens calculation method such as SRK/T formula [1]. Further supplementary data was presented regarding the evaluation of the extent of Rx alterations with Axial Length (AL) elongation using this calculation method.
Rx were calculated using intraocular lens power (IOL) (22.5D A-Constant 118) and various AL (23.0 to 26.0 mm) and corneal curvature (K) readings (41.00 to 44.00 D) using SRK/T formula. IOL was estimated with Rx (Plano), AL (23.2 mm) and K reading (42.00 D).