{"title":"[电离辐射对心脏起搏器功能效率的影响]。","authors":"H Röthig, D Wiedemann, T Herrmann, G Burk","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Influence of functions of cardiac pace-makers by ionizing radiation are represented, that is characterized in praxis relevant parameters as pulse duration and sensitivity in a special clear manner. For these parameters dose limits were defined in a phantom where tolerance ranges of pace-makers, guaranteed by producer, were over or underdosed. These dose values were different in dependence of installed electronic wiring diagrams. The radioresistance of pace-makers with Lewicki-wiring diagram (MCP 211 L) was higher than those with wiring diagram U 115. Measurings showed that the upper dose limits were greater than the known values with 60Co- and 9-MV-roentgen braking radiation and with that the complete programming and functional capacity of the pace-makers were conserved. The close cooperation of radiologists, physicists, cardiologists and technicians in the implantation clinic guarantees a good care for patients with pace-makers during radiotherapy without complications.</p>","PeriodicalId":76404,"journal":{"name":"Radiobiologia, radiotherapia","volume":"31 4","pages":"341-50"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The functional efficiency of cardiac pacemakers as affected by ionizing radiation].\",\"authors\":\"H Röthig, D Wiedemann, T Herrmann, G Burk\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Influence of functions of cardiac pace-makers by ionizing radiation are represented, that is characterized in praxis relevant parameters as pulse duration and sensitivity in a special clear manner. For these parameters dose limits were defined in a phantom where tolerance ranges of pace-makers, guaranteed by producer, were over or underdosed. These dose values were different in dependence of installed electronic wiring diagrams. The radioresistance of pace-makers with Lewicki-wiring diagram (MCP 211 L) was higher than those with wiring diagram U 115. Measurings showed that the upper dose limits were greater than the known values with 60Co- and 9-MV-roentgen braking radiation and with that the complete programming and functional capacity of the pace-makers were conserved. The close cooperation of radiologists, physicists, cardiologists and technicians in the implantation clinic guarantees a good care for patients with pace-makers during radiotherapy without complications.</p>\",\"PeriodicalId\":76404,\"journal\":{\"name\":\"Radiobiologia, radiotherapia\",\"volume\":\"31 4\",\"pages\":\"341-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiobiologia, radiotherapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiobiologia, radiotherapia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[The functional efficiency of cardiac pacemakers as affected by ionizing radiation].
Influence of functions of cardiac pace-makers by ionizing radiation are represented, that is characterized in praxis relevant parameters as pulse duration and sensitivity in a special clear manner. For these parameters dose limits were defined in a phantom where tolerance ranges of pace-makers, guaranteed by producer, were over or underdosed. These dose values were different in dependence of installed electronic wiring diagrams. The radioresistance of pace-makers with Lewicki-wiring diagram (MCP 211 L) was higher than those with wiring diagram U 115. Measurings showed that the upper dose limits were greater than the known values with 60Co- and 9-MV-roentgen braking radiation and with that the complete programming and functional capacity of the pace-makers were conserved. The close cooperation of radiologists, physicists, cardiologists and technicians in the implantation clinic guarantees a good care for patients with pace-makers during radiotherapy without complications.