额定危险电气设备和电弧闪光危险

R. Mendler, R. Hasan, Jean-Baptiste Trolle, Nabil L. Mina
{"title":"额定危险电气设备和电弧闪光危险","authors":"R. Mendler, R. Hasan, Jean-Baptiste Trolle, Nabil L. Mina","doi":"10.1109/TIA.2015.2424881","DOIUrl":null,"url":null,"abstract":"This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.","PeriodicalId":264800,"journal":{"name":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","volume":"133 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Hazardous Rated Electrical Equipment and the Arc Flash Hazard\",\"authors\":\"R. Mendler, R. Hasan, Jean-Baptiste Trolle, Nabil L. Mina\",\"doi\":\"10.1109/TIA.2015.2424881\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.\",\"PeriodicalId\":264800,\"journal\":{\"name\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":\"133 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIA.2015.2424881\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIA.2015.2424881","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文评价了危险额定电气设备之间的关系;适合安装在I类1区(1区)或2区(2区)位置的设备,以及额定电弧开关设备;设计用于承受内部电弧故障影响的设备。使用UL 1203(危险(分类)场所使用的防爆和防尘点火电气设备),IEEE C37.20.7 (IEEE内部电弧故障额定不超过38 kV的金属封闭开关设备测试指南),以及Ralph H. Lee题为“电弧产生的压力”的论文,本文将探讨额定危险设备在保护人员免受电弧闪光危害方面的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hazardous Rated Electrical Equipment and the Arc Flash Hazard
This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信