{"title":"额定危险电气设备和电弧闪光危险","authors":"R. Mendler, R. Hasan, Jean-Baptiste Trolle, Nabil L. Mina","doi":"10.1109/TIA.2015.2424881","DOIUrl":null,"url":null,"abstract":"This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.","PeriodicalId":264800,"journal":{"name":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","volume":"133 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Hazardous Rated Electrical Equipment and the Arc Flash Hazard\",\"authors\":\"R. Mendler, R. Hasan, Jean-Baptiste Trolle, Nabil L. Mina\",\"doi\":\"10.1109/TIA.2015.2424881\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.\",\"PeriodicalId\":264800,\"journal\":{\"name\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":\"133 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIA.2015.2424881\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIA.2015.2424881","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
本文评价了危险额定电气设备之间的关系;适合安装在I类1区(1区)或2区(2区)位置的设备,以及额定电弧开关设备;设计用于承受内部电弧故障影响的设备。使用UL 1203(危险(分类)场所使用的防爆和防尘点火电气设备),IEEE C37.20.7 (IEEE内部电弧故障额定不超过38 kV的金属封闭开关设备测试指南),以及Ralph H. Lee题为“电弧产生的压力”的论文,本文将探讨额定危险设备在保护人员免受电弧闪光危害方面的适用性。
Hazardous Rated Electrical Equipment and the Arc Flash Hazard
This paper evaluates the relationship between Hazardous Rated Electrical Equipment; equipment which is suitable for installation in Class I, Division 1 (Zone 1) or Division 2 (Zone 2) locations, and Arc Rated Switchgear; equipment designed to withstand the effects of an internal arcing fault. Using UL 1203 (Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for use in Hazardous (Classified) Locations), IEEE C37.20.7 (IEEE Guide for Testing Metal Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults), and the Ralph H. Lee paper titled “Pressure Developed by Arcs”, this paper will explore the applicability of Hazardous Rated Equipment in the protection of personnel from an Arc Flash Hazard.