{"title":"高频谐振MOS-FET DC-DC变换器","authors":"K. Karube, T. Nomura, T. Nakano","doi":"10.1109/PESC.1988.18112","DOIUrl":null,"url":null,"abstract":"The authors explain the operation of a 100 W half-bridge resonant DC-DC converter, the method of determining the LC constants, and the condition of gate drive for achieving no-loss switching. Since the circuit operation is of a zero-volt-switching type, the switching loss at turn-off as well as turn-on can be zeroed by strengthening the gate drive circuit. It is confirmed that the LC constants can be determined by using a simple circuit model, and that setting a low resonant capacitor voltage is effective for reducing the main circuit loss. The characteristics of some DC-DC converters trial-manufactured on the basis of these results are shown.<<ETX>>","PeriodicalId":283605,"journal":{"name":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","volume":"239 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"High frequency resonant MOS-FET DC-DC converter\",\"authors\":\"K. Karube, T. Nomura, T. Nakano\",\"doi\":\"10.1109/PESC.1988.18112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors explain the operation of a 100 W half-bridge resonant DC-DC converter, the method of determining the LC constants, and the condition of gate drive for achieving no-loss switching. Since the circuit operation is of a zero-volt-switching type, the switching loss at turn-off as well as turn-on can be zeroed by strengthening the gate drive circuit. It is confirmed that the LC constants can be determined by using a simple circuit model, and that setting a low resonant capacitor voltage is effective for reducing the main circuit loss. The characteristics of some DC-DC converters trial-manufactured on the basis of these results are shown.<<ETX>>\",\"PeriodicalId\":283605,\"journal\":{\"name\":\"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"239 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1988.18112\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1988.18112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The authors explain the operation of a 100 W half-bridge resonant DC-DC converter, the method of determining the LC constants, and the condition of gate drive for achieving no-loss switching. Since the circuit operation is of a zero-volt-switching type, the switching loss at turn-off as well as turn-on can be zeroed by strengthening the gate drive circuit. It is confirmed that the LC constants can be determined by using a simple circuit model, and that setting a low resonant capacitor voltage is effective for reducing the main circuit loss. The characteristics of some DC-DC converters trial-manufactured on the basis of these results are shown.<>