并网太阳能逆变器基于观测器的传感器容错

Andres Salazar-Llinas, A. Ginart, C. Restrepo
{"title":"并网太阳能逆变器基于观测器的传感器容错","authors":"Andres Salazar-Llinas, A. Ginart, C. Restrepo","doi":"10.1109/GREENTECH.2014.16","DOIUrl":null,"url":null,"abstract":"Grid-tied Solar Inverters rely heavily on the current sensor information to fulfill all the complex tasks associated to deliver appropriate power to the energy system with low distortion. Sensing voltage and current are an essential part of the feedback current control loop for any grid tied-solar inverter. When the sensed signal is lost, the inverter output could become unstable thus having, as a consequence, over-current situations, and other undesired power generation conditions that could lead to the catastrophic failure of the inverter. To overcome this issue, a fault-tolerant system is proposed using an observer structure designed as a way to make a 3 phase inverter current control system immune to any fault or lost of its sensing capabilities. The sensor verification is made by a smart control capable of monitoring the physical sensor operation and switch to the synthetics sensors in case of physical damage of the equipment. The proposed technique is verified by inserting a sensor fault in the system. Under this condition a good performance of the proposed fault tolerant structure is observed. The fault tolerant scheme is able to follow and determine the sensing signal lost or corrupted and seemliness continue the operation of the inverter, notified of the fault situation and wait planned shutdown is scheduled.","PeriodicalId":194092,"journal":{"name":"2014 Sixth Annual IEEE Green Technologies Conference","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Observer Based Sensor Fault Tolerant for Grid Tied - Solar Inverters\",\"authors\":\"Andres Salazar-Llinas, A. Ginart, C. Restrepo\",\"doi\":\"10.1109/GREENTECH.2014.16\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Grid-tied Solar Inverters rely heavily on the current sensor information to fulfill all the complex tasks associated to deliver appropriate power to the energy system with low distortion. Sensing voltage and current are an essential part of the feedback current control loop for any grid tied-solar inverter. When the sensed signal is lost, the inverter output could become unstable thus having, as a consequence, over-current situations, and other undesired power generation conditions that could lead to the catastrophic failure of the inverter. To overcome this issue, a fault-tolerant system is proposed using an observer structure designed as a way to make a 3 phase inverter current control system immune to any fault or lost of its sensing capabilities. The sensor verification is made by a smart control capable of monitoring the physical sensor operation and switch to the synthetics sensors in case of physical damage of the equipment. The proposed technique is verified by inserting a sensor fault in the system. Under this condition a good performance of the proposed fault tolerant structure is observed. The fault tolerant scheme is able to follow and determine the sensing signal lost or corrupted and seemliness continue the operation of the inverter, notified of the fault situation and wait planned shutdown is scheduled.\",\"PeriodicalId\":194092,\"journal\":{\"name\":\"2014 Sixth Annual IEEE Green Technologies Conference\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Sixth Annual IEEE Green Technologies Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GREENTECH.2014.16\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Sixth Annual IEEE Green Technologies Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GREENTECH.2014.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

并网太阳能逆变器在很大程度上依赖于当前传感器信息来完成所有相关的复杂任务,以低失真的方式向能源系统提供适当的功率。电压电流传感是并网太阳能逆变器电流反馈控制回路的重要组成部分。当检测信号丢失时,逆变器输出可能变得不稳定,因此,过流情况和其他不希望的发电条件可能导致逆变器的灾难性故障。为了克服这一问题,提出了一种容错系统,采用观测器结构设计,使三相逆变器电流控制系统不受任何故障或失去其传感能力的影响。传感器验证由智能控制器进行,该智能控制器能够监控物理传感器的操作,并在设备发生物理损坏时切换到合成传感器。通过在系统中插入传感器故障,验证了所提出的技术。在此条件下,所提出的容错结构具有良好的性能。容错方案能够跟踪和判断传感信号丢失或损坏,并适当地继续逆变器的运行,通知故障情况并等待计划停机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Observer Based Sensor Fault Tolerant for Grid Tied - Solar Inverters
Grid-tied Solar Inverters rely heavily on the current sensor information to fulfill all the complex tasks associated to deliver appropriate power to the energy system with low distortion. Sensing voltage and current are an essential part of the feedback current control loop for any grid tied-solar inverter. When the sensed signal is lost, the inverter output could become unstable thus having, as a consequence, over-current situations, and other undesired power generation conditions that could lead to the catastrophic failure of the inverter. To overcome this issue, a fault-tolerant system is proposed using an observer structure designed as a way to make a 3 phase inverter current control system immune to any fault or lost of its sensing capabilities. The sensor verification is made by a smart control capable of monitoring the physical sensor operation and switch to the synthetics sensors in case of physical damage of the equipment. The proposed technique is verified by inserting a sensor fault in the system. Under this condition a good performance of the proposed fault tolerant structure is observed. The fault tolerant scheme is able to follow and determine the sensing signal lost or corrupted and seemliness continue the operation of the inverter, notified of the fault situation and wait planned shutdown is scheduled.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信