耳语听力测试与筛选耳声发射在听力损失检测中的准确性

Michaela Bukvová, Hana Faitlová, Vít Blanař, J. Vodička
{"title":"耳语听力测试与筛选耳声发射在听力损失检测中的准确性","authors":"Michaela Bukvová, Hana Faitlová, Vít Blanař, J. Vodička","doi":"10.48095/ccorl20238","DOIUrl":null,"url":null,"abstract":"Summary Introduction: The aim of this paper is to evaluate the ability of a whisper hearing test together with an examination of transiently evoked otoacoustic emissions (TEOAE) to detect a hearing loss at the first contact with an adult patient with the indicated hearing impairment. This can be helpful in situations when a threshold pure tone audiometry cannot be performed. Methodology: We included a group of patients who were examined simultaneously with a classical whisper hearing test, TEOAE and a pure tone audiometry at the Department of Otorhinolaryngology and Head and Neck Surgery of the Pardubice Hospital. Sixty-two patients with a hearing impairment and 14 healthy subjects were tested. Results: A sensitivity of the whisper hearing test alone was 85% and that of TEOAE was 71%. The sensitivity increased to 94%, when both of them were used. At the same time, a relatively high specificity (75%) of the examination was present. Using the whisper hearing test and TEOAE, we did not detect 3.3% of patients with hearing loss detected by pure tone audiometry. Conclusion: In the situation when no pure tone audiometry is available a combination of the whisper hearing test and TEOAE may be used to detect a hearing loss. The combination of these two methods can be considered for a recently much-discussed screening for hearing impairment in the elderly. Key words whisper hearing test – transient evoked otoacoustic emissions – TEOAE – hearing loss – screening","PeriodicalId":423943,"journal":{"name":"Otorinolaryngologie a foniatrie","volume":"487 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An accuracy of whisper hearing test together with screening otoacoustic emissions in the detection of hearing loss\",\"authors\":\"Michaela Bukvová, Hana Faitlová, Vít Blanař, J. Vodička\",\"doi\":\"10.48095/ccorl20238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary Introduction: The aim of this paper is to evaluate the ability of a whisper hearing test together with an examination of transiently evoked otoacoustic emissions (TEOAE) to detect a hearing loss at the first contact with an adult patient with the indicated hearing impairment. This can be helpful in situations when a threshold pure tone audiometry cannot be performed. Methodology: We included a group of patients who were examined simultaneously with a classical whisper hearing test, TEOAE and a pure tone audiometry at the Department of Otorhinolaryngology and Head and Neck Surgery of the Pardubice Hospital. Sixty-two patients with a hearing impairment and 14 healthy subjects were tested. Results: A sensitivity of the whisper hearing test alone was 85% and that of TEOAE was 71%. The sensitivity increased to 94%, when both of them were used. At the same time, a relatively high specificity (75%) of the examination was present. Using the whisper hearing test and TEOAE, we did not detect 3.3% of patients with hearing loss detected by pure tone audiometry. Conclusion: In the situation when no pure tone audiometry is available a combination of the whisper hearing test and TEOAE may be used to detect a hearing loss. The combination of these two methods can be considered for a recently much-discussed screening for hearing impairment in the elderly. Key words whisper hearing test – transient evoked otoacoustic emissions – TEOAE – hearing loss – screening\",\"PeriodicalId\":423943,\"journal\":{\"name\":\"Otorinolaryngologie a foniatrie\",\"volume\":\"487 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Otorinolaryngologie a foniatrie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.48095/ccorl20238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otorinolaryngologie a foniatrie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48095/ccorl20238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要简介:本文的目的是评估耳语听力测试和瞬时诱发耳声发射(TEOAE)检查在首次接触有听力障碍的成年患者时检测听力损失的能力。这在阈值纯音测听无法执行的情况下很有帮助。方法:我们纳入了一组患者,他们同时接受了Pardubice医院耳鼻喉科和头颈外科的经典耳语听力测试、TEOAE和纯音听力测试。对62名听力障碍患者和14名健康受试者进行了测试。结果:单独耳语听力测试的灵敏度为85%,TEOAE的灵敏度为71%。当两者同时使用时,灵敏度提高到94%。同时,该检查具有较高的特异性(75%)。使用耳语听力测试和TEOAE,我们没有检测到3.3%的纯音听力测定检测到的听力损失患者。结论:在没有纯音测听的情况下,耳语听力测试和TEOAE联合检测听力损失是可行的。这两种方法的结合可以考虑用于最近讨论较多的老年人听力障碍筛查。【关键词】耳语听力测试;瞬态诱发耳声发射;TEOAE
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An accuracy of whisper hearing test together with screening otoacoustic emissions in the detection of hearing loss
Summary Introduction: The aim of this paper is to evaluate the ability of a whisper hearing test together with an examination of transiently evoked otoacoustic emissions (TEOAE) to detect a hearing loss at the first contact with an adult patient with the indicated hearing impairment. This can be helpful in situations when a threshold pure tone audiometry cannot be performed. Methodology: We included a group of patients who were examined simultaneously with a classical whisper hearing test, TEOAE and a pure tone audiometry at the Department of Otorhinolaryngology and Head and Neck Surgery of the Pardubice Hospital. Sixty-two patients with a hearing impairment and 14 healthy subjects were tested. Results: A sensitivity of the whisper hearing test alone was 85% and that of TEOAE was 71%. The sensitivity increased to 94%, when both of them were used. At the same time, a relatively high specificity (75%) of the examination was present. Using the whisper hearing test and TEOAE, we did not detect 3.3% of patients with hearing loss detected by pure tone audiometry. Conclusion: In the situation when no pure tone audiometry is available a combination of the whisper hearing test and TEOAE may be used to detect a hearing loss. The combination of these two methods can be considered for a recently much-discussed screening for hearing impairment in the elderly. Key words whisper hearing test – transient evoked otoacoustic emissions – TEOAE – hearing loss – screening
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信