A. Sauhats, J. Kozadajevs, A. Dolgicers, I. Zālītis, D. Boreiko
{"title":"区域供热系统热惯性对热电联产运行方式的影响","authors":"A. Sauhats, J. Kozadajevs, A. Dolgicers, I. Zālītis, D. Boreiko","doi":"10.1109/RTUCON48111.2019.8982254","DOIUrl":null,"url":null,"abstract":"About 8% of all the world's electricity is generated by means of combined heat and power plants (CHPPs). The main thermal load for CHPPs in Nordic countries is constituted by the district heating system. In operation according to the heat schedule during the heating season, CHPP operation mode forecasting inaccuracy is often observed. Heat consumption foremost depends on outdoor temperature. Forecasting of the temperature, which lies at the basis of the CHPP operation mode forecast, is a complicated task even for a period of 24 hours and always involves forecasting inaccuracy, which in turn leads to CHPP operation mode forecasting inaccuracy. The problem is that, based on the heat load forecast, a calculation of the electricity produced by the CHPP in cogeneration mode is announced to the Nord Pool Spot. In this study, we will investigate what changes in building indoor temperature may occur if the CHPP operates according to the forecast heat load mode instead of operating based on actual heat demand.","PeriodicalId":317349,"journal":{"name":"2019 IEEE 60th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Impact of the District Heating System Thermal Inertia on the CHPP Operation Mode\",\"authors\":\"A. Sauhats, J. Kozadajevs, A. Dolgicers, I. Zālītis, D. Boreiko\",\"doi\":\"10.1109/RTUCON48111.2019.8982254\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"About 8% of all the world's electricity is generated by means of combined heat and power plants (CHPPs). The main thermal load for CHPPs in Nordic countries is constituted by the district heating system. In operation according to the heat schedule during the heating season, CHPP operation mode forecasting inaccuracy is often observed. Heat consumption foremost depends on outdoor temperature. Forecasting of the temperature, which lies at the basis of the CHPP operation mode forecast, is a complicated task even for a period of 24 hours and always involves forecasting inaccuracy, which in turn leads to CHPP operation mode forecasting inaccuracy. The problem is that, based on the heat load forecast, a calculation of the electricity produced by the CHPP in cogeneration mode is announced to the Nord Pool Spot. In this study, we will investigate what changes in building indoor temperature may occur if the CHPP operates according to the forecast heat load mode instead of operating based on actual heat demand.\",\"PeriodicalId\":317349,\"journal\":{\"name\":\"2019 IEEE 60th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 60th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTUCON48111.2019.8982254\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 60th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON48111.2019.8982254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Impact of the District Heating System Thermal Inertia on the CHPP Operation Mode
About 8% of all the world's electricity is generated by means of combined heat and power plants (CHPPs). The main thermal load for CHPPs in Nordic countries is constituted by the district heating system. In operation according to the heat schedule during the heating season, CHPP operation mode forecasting inaccuracy is often observed. Heat consumption foremost depends on outdoor temperature. Forecasting of the temperature, which lies at the basis of the CHPP operation mode forecast, is a complicated task even for a period of 24 hours and always involves forecasting inaccuracy, which in turn leads to CHPP operation mode forecasting inaccuracy. The problem is that, based on the heat load forecast, a calculation of the electricity produced by the CHPP in cogeneration mode is announced to the Nord Pool Spot. In this study, we will investigate what changes in building indoor temperature may occur if the CHPP operates according to the forecast heat load mode instead of operating based on actual heat demand.