T. Uchii, K. Iwata, H. Kawano, T. Nakamoto, K. Suzuki
{"title":"气体断路器中非均匀高温SF/sub - 6/气体的行为","authors":"T. Uchii, K. Iwata, H. Kawano, T. Nakamoto, K. Suzuki","doi":"10.1109/PESW.2001.917050","DOIUrl":null,"url":null,"abstract":"The purpose of the present paper is to show the dielectric characteristics of inhomogeneous hot SF/sub 6/ gas in a gas circuit breaker (GCB) experimentally. High-temperature and low-density SF/sub 6/ gas generated by a heavy current interruption is distributed inhomogeneously in the grounded tank, and can strongly threaten the dielectric capability of the GCB. Few studies, however, have been carried out on the dielectric characteristics of the inhomogeneous hot gas. Using small gap discharges, the hot gas behavior of a GCB model, having breakdown or no breakdown, was investigated. The temperature of the hot gas flowing through the exhaust tube was estimated from the sparking voltage of the small gap installed in the exhaust tube. It was also found that there was very little or no effect on breakdown voltages of the cool gas in the breakdown paths. This suggests that the breakdown voltage of inhomogeneous hot gas could be obtained as the applied voltage at which the electrical field strength equals E/sub crit/ of local hot gas at the location concerned.","PeriodicalId":253534,"journal":{"name":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Behavior of inhomogeneous high-temperature SF/sub 6/ gas in a gas circuit breaker\",\"authors\":\"T. Uchii, K. Iwata, H. Kawano, T. Nakamoto, K. Suzuki\",\"doi\":\"10.1109/PESW.2001.917050\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of the present paper is to show the dielectric characteristics of inhomogeneous hot SF/sub 6/ gas in a gas circuit breaker (GCB) experimentally. High-temperature and low-density SF/sub 6/ gas generated by a heavy current interruption is distributed inhomogeneously in the grounded tank, and can strongly threaten the dielectric capability of the GCB. Few studies, however, have been carried out on the dielectric characteristics of the inhomogeneous hot gas. Using small gap discharges, the hot gas behavior of a GCB model, having breakdown or no breakdown, was investigated. The temperature of the hot gas flowing through the exhaust tube was estimated from the sparking voltage of the small gap installed in the exhaust tube. It was also found that there was very little or no effect on breakdown voltages of the cool gas in the breakdown paths. This suggests that the breakdown voltage of inhomogeneous hot gas could be obtained as the applied voltage at which the electrical field strength equals E/sub crit/ of local hot gas at the location concerned.\",\"PeriodicalId\":253534,\"journal\":{\"name\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2001.917050\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2001.917050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Behavior of inhomogeneous high-temperature SF/sub 6/ gas in a gas circuit breaker
The purpose of the present paper is to show the dielectric characteristics of inhomogeneous hot SF/sub 6/ gas in a gas circuit breaker (GCB) experimentally. High-temperature and low-density SF/sub 6/ gas generated by a heavy current interruption is distributed inhomogeneously in the grounded tank, and can strongly threaten the dielectric capability of the GCB. Few studies, however, have been carried out on the dielectric characteristics of the inhomogeneous hot gas. Using small gap discharges, the hot gas behavior of a GCB model, having breakdown or no breakdown, was investigated. The temperature of the hot gas flowing through the exhaust tube was estimated from the sparking voltage of the small gap installed in the exhaust tube. It was also found that there was very little or no effect on breakdown voltages of the cool gas in the breakdown paths. This suggests that the breakdown voltage of inhomogeneous hot gas could be obtained as the applied voltage at which the electrical field strength equals E/sub crit/ of local hot gas at the location concerned.