RTV镀膜玻璃绝缘子应用于高湿地区,降低输电线路停电风险

T. Mustafa, L. Meyer, S. Cabral, H. Almaguer, L. Puchale, J. E. M. Cereia, G. B. Vier, Alysson Caye
{"title":"RTV镀膜玻璃绝缘子应用于高湿地区,降低输电线路停电风险","authors":"T. Mustafa, L. Meyer, S. Cabral, H. Almaguer, L. Puchale, J. E. M. Cereia, G. B. Vier, Alysson Caye","doi":"10.1109/ICECCME55909.2022.9987949","DOIUrl":null,"url":null,"abstract":"This paper presents a successful trial that has been applied by a Brazilian power utility company to mitigate the excessive outage rate due to the air humidity of a 230 kV power transmission line. In this study, it was used insulators with Room Temperature Vulcanized Silicone Rubber. This transmission line has experienced a history of numerous outages during winter when humidity is high. Most of the outages have been identified as caused by sudden flashover and associated single-phase faults randomly located over the line length, which motivated the development of studies to identify their main reasons. A milestone study identified the correlation between the behavior of the relative air humidity and the rate of the line's protection tripping. Based on that and other studies, this work brings the analysis of the performance of four different string configurations using RTV coated insulators as a permanent solution to mitigate the relatively high rate of line outages.","PeriodicalId":202568,"journal":{"name":"2022 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"RTV Coated Glass Insulators Applied in High Humidity Areas to Reduce the Risk of Transmission Line Outage\",\"authors\":\"T. Mustafa, L. Meyer, S. Cabral, H. Almaguer, L. Puchale, J. E. M. Cereia, G. B. Vier, Alysson Caye\",\"doi\":\"10.1109/ICECCME55909.2022.9987949\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a successful trial that has been applied by a Brazilian power utility company to mitigate the excessive outage rate due to the air humidity of a 230 kV power transmission line. In this study, it was used insulators with Room Temperature Vulcanized Silicone Rubber. This transmission line has experienced a history of numerous outages during winter when humidity is high. Most of the outages have been identified as caused by sudden flashover and associated single-phase faults randomly located over the line length, which motivated the development of studies to identify their main reasons. A milestone study identified the correlation between the behavior of the relative air humidity and the rate of the line's protection tripping. Based on that and other studies, this work brings the analysis of the performance of four different string configurations using RTV coated insulators as a permanent solution to mitigate the relatively high rate of line outages.\",\"PeriodicalId\":202568,\"journal\":{\"name\":\"2022 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECCME55909.2022.9987949\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECCME55909.2022.9987949","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了巴西一家电力公司为缓解230千伏输电线路因空气湿度过大而导致的停电率而进行的成功试验。本研究采用常温硫化硅橡胶作为绝缘子。这条输电线路在冬季湿度高时经历了多次停电。大多数停电被认为是由突然闪络和随机分布在线路长度上的单相故障引起的,这促使人们开展研究以确定其主要原因。一项里程碑式的研究确定了相对空气湿度的行为与线路保护跳闸率之间的相关性。在此基础上,本研究分析了采用RTV涂层绝缘子作为永久解决方案的四种不同管柱配置的性能,以降低相对较高的线路中断率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
RTV Coated Glass Insulators Applied in High Humidity Areas to Reduce the Risk of Transmission Line Outage
This paper presents a successful trial that has been applied by a Brazilian power utility company to mitigate the excessive outage rate due to the air humidity of a 230 kV power transmission line. In this study, it was used insulators with Room Temperature Vulcanized Silicone Rubber. This transmission line has experienced a history of numerous outages during winter when humidity is high. Most of the outages have been identified as caused by sudden flashover and associated single-phase faults randomly located over the line length, which motivated the development of studies to identify their main reasons. A milestone study identified the correlation between the behavior of the relative air humidity and the rate of the line's protection tripping. Based on that and other studies, this work brings the analysis of the performance of four different string configurations using RTV coated insulators as a permanent solution to mitigate the relatively high rate of line outages.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信